← Colorado

Tap water quality report

Montezuma Wc

EPA monitoring tested this supplier for 109 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
14
detected
13,797
people served
0
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Montezuma

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
41
violations on file
2
still open
ViolationTypeStatusPeriod
Other Monitoring Resolved 2025-07-01
Other Monitoring Resolved 2025-07-01
Other Monitoring Resolved 2025-07-01
MR Monitoring Unaddressed 2025-01-01
MR Monitoring Unaddressed 2025-01-01
MR Monitoring Resolved 2024-09-01 → 2024-09-30
MR Monitoring Resolved 2024-09-01 → 2024-09-30
MR Monitoring Resolved 2024-09-01 → 2024-09-30
MR Monitoring Resolved 2024-09-01 → 2024-09-30
MR Monitoring Resolved 2024-09-01 → 2024-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
32.575 µg/L 41%
of the EPA limit 80 µg/L
worst single sample: 37.8 µg/L
106/106 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
39 µg/L 65%
of the EPA limit 60 µg/L
worst single sample: 51.2 µg/L
106/106 SYR4 2012–2019
Chlorite
495 µg/L 50%
of the EPA limit 1000 µg/L
worst single sample: 620 µg/L
96/96 SYR4 2012–2019
Bromodichloromethane
6.78 µg/L
No EPA limit set
worst single sample: 7.8 µg/L
57/57 SYR4 2012–2019
Chloroform
24.2 µg/L
No EPA limit set
worst single sample: 29 µg/L
57/57 SYR4 2012–2019
Dichloroacetic Acid
23.35 µg/L
No EPA limit set
worst single sample: 26 µg/L
54/54 SYR4 2015–2019
Trichloroacetic Acid
15.35 µg/L
No EPA limit set
worst single sample: 18 µg/L
54/54 SYR4 2015–2019
Dibromochloromethane
1.435 µg/L
No EPA limit set
worst single sample: 1.9 µg/L
34/57 SYR4 2012–2019
Lead
0.0029 mg/L 19%
of the EPA limit 0.0150 mg/L
20/20 LCR 2025
Monochloroacetic Acid
3.42 µg/L
No EPA limit set
worst single sample: 3.5 µg/L
5/54 SYR4 2015–2019
Lithium
29.1 µg/L
No EPA limit set
4/4 UCMR-5 2025
Barium
95 µg/L 4.8%
of the EPA limit 2000 µg/L
1/1 SYR4 2012
Combined Uranium
0.1900 µg/L 0.6%
of the EPA limit 30 µg/L
1/1 SYR4 2014
Gross Alpha, Excl. Radon And U
2.8 pCi/L 19%
of the EPA limit 15 pCi/L
1/1 SYR4 2014
95 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneFluorideGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidNetfosaaNfdhaNmefosaaNitrateNitrate-NitriteNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
BOWMAN, STEVE
Phone
970-882-2226
Email
[email protected]

Frequently asked questions about Montezuma Wc

Is Montezuma Wc tap water safe to drink?

EPA monitoring detected 14 contaminants in Montezuma Wc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Montezuma Wc's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Chlorite, Bromodichloromethane, Chloroform, and others. The full list with the level and data source for each is above.

How many people does Montezuma Wc serve?

Montezuma Wc reports serving 13,797 people in Colorado, per its EPA record.

Has Montezuma Wc had any water quality violations?

The EPA has 41 violations on file for Montezuma Wc, of which 0 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.