← Colorado

Tap water quality report

Narrow Gauge Mhp

EPA monitoring tested this supplier for 12 contaminants and detected 8. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

12
contaminants tested
8
detected
150
people served
0
health-based violations
Water source
SWP
Ownership
Private
Counties served
La Plata

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
428
violations on file
4
still open
ViolationTypeStatusPeriod
Other Monitoring Unaddressed 2025-07-01
Other Monitoring Unaddressed 2025-07-01
Other Monitoring Unaddressed 2024-07-01
Other Monitoring Unaddressed 2024-07-01
MR Monitoring Resolved 2019-01-01 → 2019-03-31
MR Monitoring Resolved 2019-01-01 → 2019-03-31
MR Monitoring Resolved 2019-01-01 → 2019-03-31
MR Monitoring Resolved 2019-01-01 → 2019-03-31
MR Monitoring Resolved 2019-01-01 → 2019-03-31
MR Monitoring Resolved 2019-01-01 → 2019-03-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.00030 mg/L 2%
of the EPA limit 0.0150 mg/L
15/15 LCR 2025
TTHM
48.985 µg/L 61%
of the EPA limit 80 µg/L
worst single sample: 51.1 µg/L
10/10 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
76.66 µg/L 128%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 77.1 µg/L
9/10 SYR4 2013–2019
Bromodichloromethane
4.5515 µg/L
No EPA limit set
worst single sample: 4.56 µg/L
2/2 SYR4 2018–2019
Chloroform
25.4 µg/L
No EPA limit set
worst single sample: 25.5 µg/L
2/2 SYR4 2018–2019
Dibromochloromethane
0.6070 µg/L
No EPA limit set
worst single sample: 0.6100 µg/L
2/2 SYR4 2018–2019
Dichloroacetic Acid
14.945 µg/L
No EPA limit set
worst single sample: 15.2 µg/L
2/2 SYR4 2018–2019
Trichloroacetic Acid
15.64 µg/L
No EPA limit set
worst single sample: 15.8 µg/L
2/2 SYR4 2018–2019
4 contaminants tested, none detected
BromoformDibromoacetic AcidMonobromoacetic AcidMonochloroacetic Acid

Utility contact

Contact
ELLIS, JANELLE
Phone
970-247-3082
Email
[email protected]

Frequently asked questions about Narrow Gauge Mhp

Is Narrow Gauge Mhp tap water safe to drink?

EPA monitoring detected 8 contaminants in Narrow Gauge Mhp's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Narrow Gauge Mhp's water?

EPA monitoring detected Lead, TTHM, Total Haloacetic Acids (HAA5), Bromodichloromethane, Chloroform, and others. The full list with the level and data source for each is above.

How many people does Narrow Gauge Mhp serve?

Narrow Gauge Mhp reports serving 150 people in Colorado, per its EPA record.

Has Narrow Gauge Mhp had any water quality violations?

The EPA has 428 violations on file for Narrow Gauge Mhp, of which 0 are health-based (a contaminant limit or required treatment was breached) and 4 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.