← Colorado

Tap water quality report

North Valley Subdivision Utility Company

EPA monitoring tested this supplier for 77 contaminants and detected 19. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

77
contaminants tested
19
detected
79
people served
0
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Gunnison

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
22
violations on file
0
still open
ViolationTypeStatusPeriod
Other Monitoring Resolved 2023-07-11
Other Monitoring Resolved 2023-07-11
Other Monitoring Resolved 2023-07-11
Other Monitoring Resolved 2023-07-01
Other Monitoring Resolved 2023-07-01
Other Monitoring Resolved 2023-07-01
MON Monitoring Resolved 2022-05-01 → 2022-05-31
MON Monitoring Resolved 2022-05-01 → 2022-05-31
MON Monitoring Resolved 2022-05-01 → 2022-05-31
MR Monitoring Resolved 2022-04-01 → 2022-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
4600 µg/L 46%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
15/15 LCR 2025
Barium
95.7 µg/L 4.8%
of the EPA limit 2000 µg/L
worst single sample: 97 µg/L
3/3 SYR4 2012–2018
Bromoform
7.29 µg/L
No EPA limit set
worst single sample: 7.7 µg/L
3/3 SYR4 2012–2018
Fluoride
317 µg/L 7.9%
of the EPA limit 4000 µg/L
worst single sample: 320 µg/L
3/3 SYR4 2012–2018
Selenium
2.9 µg/L 5.8%
of the EPA limit 50 µg/L
worst single sample: 3 µg/L
3/3 SYR4 2012–2018
TTHM
12.63 µg/L 16%
of the EPA limit 80 µg/L
worst single sample: 12.8 µg/L
3/3 SYR4 2012–2018
Total Haloacetic Acids (HAA5)
4.224 µg/L 7%
of the EPA limit 60 µg/L
worst single sample: 4.3 µg/L
3/3 SYR4 2012–2018
Arsenic
2 µg/L 20%
of the EPA limit 10 µg/L
2/3 SYR4 2012–2018
Bromodichloromethane
2.21 µg/L
No EPA limit set
worst single sample: 2.3 µg/L
2/3 SYR4 2012–2018
Dibromoacetic Acid
3.428 µg/L
No EPA limit set
worst single sample: 3.54 µg/L
2/2 SYR4 2015–2018
Dibromochloromethane
5.18 µg/L
No EPA limit set
worst single sample: 5.3 µg/L
2/3 SYR4 2012–2018
Chloroform
0.7800 µg/L
No EPA limit set
1/3 SYR4 2012–2018
Chromium
2 µg/L 2%
of the EPA limit 100 µg/L
1/3 SYR4 2012–2018
Combined Radium (-226 And -228)
1.8 pCi/L 36%
of the EPA limit 5 pCi/L
1/1 SYR4 2019
Combined Uranium
5 µg/L 17%
of the EPA limit 30 µg/L
1/1 SYR4 2019
Gross Alpha, Excl. Radon And U
3.85 pCi/L 26%
of the EPA limit 15 pCi/L
1/1 SYR4 2019
Hexachlorocyclopentadiene
0.0760 µg/L 0.2%
of the EPA limit 50 µg/L
1/3 SYR4 2012–2018
Nitrate-Nitrite
1800 µg/L 18%
of the EPA limit 10000 µg/L
1/1 SYR4 2018
58 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDichloroacetic AcidDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
ANDERSON, TED
Phone
970-641-2656
Email
[email protected]

Frequently asked questions about North Valley Subdivision Utility Company

Is North Valley Subdivision Utility Company tap water safe to drink?

EPA monitoring detected 19 contaminants in North Valley Subdivision Utility Company's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in North Valley Subdivision Utility Company's water?

EPA monitoring detected Nitrate, Lead, Barium, Bromoform, Fluoride, and others. The full list with the level and data source for each is above.

How many people does North Valley Subdivision Utility Company serve?

North Valley Subdivision Utility Company reports serving 79 people in Colorado, per its EPA record.

Has North Valley Subdivision Utility Company had any water quality violations?

The EPA has 22 violations on file for North Valley Subdivision Utility Company, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.