← Colorado

Tap water quality report

Park Center Wd

EPA monitoring tested this supplier for 108 contaminants and detected 21. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

108
contaminants tested
21
detected
4,000
people served
12
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Fremont

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

12
health-based violations
138
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2018-04-01 → 2018-06-30
MCL Health-based Resolved 2018-04-01 → 2018-06-30
MCL Health-based Resolved 2018-04-01 → 2018-06-30
MCL Health-based Resolved 2018-04-01 → 2018-06-30
MCL Health-based Resolved 2018-01-01 → 2018-03-31
MCL Health-based Resolved 2018-01-01 → 2018-03-31
MCL Health-based Resolved 2018-01-01 → 2018-03-31
MCL Health-based Resolved 2018-01-01 → 2018-03-31
MCL Health-based Resolved 2015-10-01 → 2015-12-31
MCL Health-based Resolved 2015-10-01 → 2015-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
116.2 µg/L 145%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 146 µg/L
62/62 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
42.62 µg/L 71%
of the EPA limit 60 µg/L
worst single sample: 59.5 µg/L
57/57 SYR4 2012–2019
Bromodichloromethane
29.66 µg/L
No EPA limit set
worst single sample: 33 µg/L
37/37 SYR4 2012–2019
Bromoform
10.94 µg/L
No EPA limit set
worst single sample: 12 µg/L
37/37 SYR4 2012–2019
Chloroform
53.88 µg/L
No EPA limit set
worst single sample: 63.2 µg/L
37/37 SYR4 2012–2019
Dibromochloromethane
25 µg/L
No EPA limit set
worst single sample: 30.5 µg/L
37/37 SYR4 2012–2019
Dibromoacetic Acid
8.26 µg/L
No EPA limit set
worst single sample: 9.6 µg/L
30/30 SYR4 2015–2019
Dichloroacetic Acid
25.22 µg/L
No EPA limit set
worst single sample: 29.2 µg/L
30/30 SYR4 2015–2019
Trichloroacetic Acid
15.295 µg/L
No EPA limit set
worst single sample: 17.6 µg/L
24/30 SYR4 2015–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
20/20 LCR 2025
Monobromoacetic Acid
1.8 µg/L
No EPA limit set
20/30 SYR4 2015–2019
Nitrate
220 µg/L 2.2%
of the EPA limit 10000 µg/L
14/20 SYR4 2012–2019
Fluoride
1910 µg/L 48%
of the EPA limit 4000 µg/L
worst single sample: 2000 µg/L
10/10 SYR4 2012–2019
Barium
18 µg/L 0.9%
of the EPA limit 2000 µg/L
9/10 SYR4 2012–2019
Selenium
2 µg/L 4%
of the EPA limit 50 µg/L
worst single sample: 2.2 µg/L
9/10 SYR4 2012–2019
Monochloroacetic Acid
10.16 µg/L
No EPA limit set
worst single sample: 10.3 µg/L
8/30 SYR4 2015–2019
Chromium
4.925 µg/L 4.9%
of the EPA limit 100 µg/L
worst single sample: 5.2 µg/L
6/10 SYR4 2012–2019
Lithium
59.6 µg/L
No EPA limit set
4/4 UCMR-5 2024
Combined Radium (-226 And -228)
0.2900 pCi/L 5.8%
of the EPA limit 5 pCi/L
worst single sample: 0.3000 pCi/L
3/3 SYR4 2016
Antimony, Total
0.4295 µg/L 7.2%
of the EPA limit 6 µg/L
worst single sample: 0.4300 µg/L
2/10 SYR4 2012–2019
Combined Uranium
0.0015 µg/L 0%
of the EPA limit 30 µg/L
1/3 SYR4 2016
87 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,3,7,8-TCDD2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGross Alpha, Excl. Radon And UHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitrate-NitriteNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
WADE, JAMES
Phone
719-275-2055
Email
[email protected]

Frequently asked questions about Park Center Wd

Is Park Center Wd tap water safe to drink?

EPA monitoring detected 21 contaminants in Park Center Wd's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Park Center Wd's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Bromodichloromethane, Bromoform, Chloroform, and others. The full list with the level and data source for each is above.

How many people does Park Center Wd serve?

Park Center Wd reports serving 4,000 people in Colorado, per its EPA record.

Has Park Center Wd had any water quality violations?

The EPA has 138 violations on file for Park Center Wd, of which 12 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.