← Colorado

Tap water quality report

Pinery Wwd

EPA monitoring tested this supplier for 109 contaminants and detected 32. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
32
detected
12,901
people served
4
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Douglas

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
327
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2019-10-01 → 2019-12-31
MCL Health-based Resolved 2019-10-01 → 2019-12-31
MCL Health-based Resolved 2019-10-01 → 2019-12-31
MCL Health-based Resolved 2019-10-01 → 2019-12-31
MR Monitoring Resolved 2025-04-01 → 2025-06-30
MR Monitoring Resolved 2025-04-01 → 2025-06-30
MR Monitoring Resolved 2025-04-01 → 2025-06-30
MR Monitoring Resolved 2025-04-01 → 2025-06-30
MR Monitoring Resolved 2025-04-01 → 2025-06-30
MR Monitoring Resolved 2025-04-01 → 2025-06-30

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
PFBS 0.0053 µg/L 4/14 2025
Pfpea 0.0096 µg/L 4/14 2025
Pfhxa 0.0081 µg/L 2/14 2025
Pfba 0.0058 µg/L 1/14 2025

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
2000 µg/L 20%
of the EPA limit 10000 µg/L
worst single sample: 2400 µg/L
100/112 SYR4 2012–2019
TTHM
54 µg/L 68%
of the EPA limit 80 µg/L
worst single sample: 57.2 µg/L
41/48 SYR4 2012–2019
Bromodichloromethane
17.735 µg/L
No EPA limit set
worst single sample: 18.5 µg/L
32/43 SYR4 2012–2019
Bromoform
6.875 µg/L
No EPA limit set
worst single sample: 7.8 µg/L
32/43 SYR4 2012–2019
Dibromochloromethane
21.955 µg/L
No EPA limit set
worst single sample: 24 µg/L
32/43 SYR4 2012–2019
Barium
246 µg/L 12%
of the EPA limit 2000 µg/L
worst single sample: 260 µg/L
29/29 SYR4 2012–2019
Fluoride
1640 µg/L 41%
of the EPA limit 4000 µg/L
worst single sample: 1900 µg/L
29/29 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
29/29 LCR 2025
Combined Radium (-226 And -228)
5.355 pCi/L 107%
of the EPA limit, at the 95th percentile of samples — 5 pCi/L
worst single sample: 6.5 pCi/L
28/28 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
18.935 µg/L 32%
of the EPA limit 60 µg/L
worst single sample: 20.7 µg/L
22/24 SYR4 2012–2019
Chloroform
9.3 µg/L
No EPA limit set
21/43 SYR4 2012–2019
Combined Uranium
24.35 µg/L 81%
of the EPA limit 30 µg/L
worst single sample: 31 µg/L
20/22 SYR4 2012–2019
Gross Alpha, Excl. Radon And U
16.191 pCi/L 108%
of the EPA limit, at the 95th percentile of samples — 15 pCi/L
worst single sample: 27.23 pCi/L
20/20 SYR4 2012–2019
Arsenic
3.86 µg/L 39%
of the EPA limit 10 µg/L
worst single sample: 4.1 µg/L
17/29 SYR4 2012–2019
Selenium
4.08 µg/L 8.2%
of the EPA limit 50 µg/L
worst single sample: 6.4 µg/L
17/29 SYR4 2012–2019
Lithium
29.5 µg/L
No EPA limit set
14/14 UCMR-5 2025
Nitrate-Nitrite
2115 µg/L 21%
of the EPA limit 10000 µg/L
worst single sample: 2500 µg/L
12/13 SYR4 2012–2019
Dibromoacetic Acid
8.855 µg/L
No EPA limit set
worst single sample: 8.9 µg/L
10/10 SYR4 2015–2019
Dichloroacetic Acid
5.75 µg/L
No EPA limit set
worst single sample: 5.9 µg/L
6/10 SYR4 2015–2019
Trichloroacetic Acid
3.375 µg/L
No EPA limit set
worst single sample: 3.4 µg/L
6/10 SYR4 2015–2019
Nitrite
111 µg/L 11%
of the EPA limit 1000 µg/L
worst single sample: 120 µg/L
3/13 SYR4 2012–2019
Hexachlorocyclopentadiene
0.0640 µg/L 0.1%
of the EPA limit 50 µg/L
worst single sample: 0.0650 µg/L
2/44 SYR4 2013–2019
Monobromoacetic Acid
1 µg/L
No EPA limit set
2/10 SYR4 2015–2019
Monochloroacetic Acid
10.4 µg/L
No EPA limit set
worst single sample: 10.7 µg/L
2/10 SYR4 2015–2019
Toluene
4.43 µg/L 0.4%
of the EPA limit 1000 µg/L
worst single sample: 4.6 µg/L
2/47 SYR4 2012–2019
Antimony, Total
2.3 µg/L 38%
of the EPA limit 6 µg/L
1/29 SYR4 2012–2019
Di(2-ethylhexyl) Phthalate
0.8600 µg/L 14%
of the EPA limit 6 µg/L
1/43 SYR4 2013–2019
Hexachlorobenzene
0.0076 µg/L 0.8%
of the EPA limit 1 µg/L
1/44 SYR4 2013–2019
77 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHfpo-DaHeptachlorHeptachlor EpoxideLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaOxamylPfdaPfdoaPfeesaPfhpaPfhpsPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
HAMMANN, DAN
Phone
303-841-2797
Email
[email protected]

Frequently asked questions about Pinery Wwd

Is Pinery Wwd tap water safe to drink?

EPA monitoring detected 32 contaminants in Pinery Wwd's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Pinery Wwd's water?

EPA monitoring detected Nitrate, TTHM, Bromodichloromethane, Bromoform, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does Pinery Wwd serve?

Pinery Wwd reports serving 12,901 people in Colorado, per its EPA record.

Has Pinery Wwd had any water quality violations?

The EPA has 327 violations on file for Pinery Wwd, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.