← Colorado

Tap water quality report

Stucker Mesa Domestic Wc

EPA monitoring tested this supplier for 80 contaminants and detected 20. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

80
contaminants tested
20
detected
36
people served
110
health-based violations
Water source
Ground water under surface influence
Ownership
Private
Counties served
Delta

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

110
health-based violations
538
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2023-04-01 → 2023-04-30
TT Health-based Resolved 2023-04-01 → 2023-04-30
TT Health-based Resolved 2023-04-01 → 2023-04-30
TT Health-based Resolved 2023-04-01 → 2023-04-30
TT Health-based Resolved 2023-04-01 → 2023-04-30
TT Health-based Resolved 2022-05-01 → 2022-05-31
TT Health-based Resolved 2022-05-01 → 2022-05-31
TT Health-based Resolved 2022-05-01 → 2022-05-31
TT Health-based Resolved 2022-05-01 → 2022-05-31
TT Health-based Resolved 2022-05-01 → 2022-05-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.00050 mg/L 3.3%
of the EPA limit 0.0150 mg/L
23/23 LCR 2025
Nitrate
300 µg/L 3%
of the EPA limit 10000 µg/L
16/18 SYR4 2012–2019
Barium
70 µg/L 3.5%
of the EPA limit 2000 µg/L
8/8 SYR4 2012–2019
Fluoride
276.5 µg/L 6.9%
of the EPA limit 4000 µg/L
worst single sample: 280 µg/L
8/8 SYR4 2012–2019
Selenium
2.6 µg/L 5.2%
of the EPA limit 50 µg/L
8/8 SYR4 2012–2019
TTHM
78.16 µg/L 98%
of the EPA limit 80 µg/L
worst single sample: 80.4 µg/L
8/8 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
22.105 µg/L 37%
of the EPA limit 60 µg/L
worst single sample: 24.1 µg/L
8/8 SYR4 2012–2019
Combined Uranium
3.855 µg/L 13%
of the EPA limit 30 µg/L
worst single sample: 3.9 µg/L
4/4 SYR4 2012–2014
Combined Radium (-226 And -228)
1.465 pCi/L 29%
of the EPA limit 5 pCi/L
worst single sample: 1.5 pCi/L
2/4 SYR4 2012–2014
Gross Alpha, Excl. Radon And U
0.6944 pCi/L 4.6%
of the EPA limit 15 pCi/L
worst single sample: 0.7000 pCi/L
2/4 SYR4 2012–2014
Arsenic
1.1 µg/L 11%
of the EPA limit 10 µg/L
1/8 SYR4 2012–2019
Bromodichloromethane
27.1 µg/L
No EPA limit set
1/1 SYR4 2019
Bromoform
1.2 µg/L
No EPA limit set
1/1 SYR4 2019
Chloroform
31.4 µg/L
No EPA limit set
1/1 SYR4 2019
Chromium
1 µg/L 1%
of the EPA limit 100 µg/L
1/8 SYR4 2012–2019
Dibromoacetic Acid
4.3 µg/L
No EPA limit set
1/1 SYR4 2019
Dibromochloromethane
14.3 µg/L
No EPA limit set
1/1 SYR4 2019
Dichloroacetic Acid
12.2 µg/L
No EPA limit set
1/1 SYR4 2019
Nitrate-Nitrite
150 µg/L 1.5%
of the EPA limit 10000 µg/L
1/1 SYR4 2014
Trichloroacetic Acid
7.6 µg/L
No EPA limit set
1/1 SYR4 2019
60 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateGross Beta Particle ActivityHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
CERIANI, PHILIP
Phone
970-260-2057
Email
[email protected]

Frequently asked questions about Stucker Mesa Domestic Wc

Is Stucker Mesa Domestic Wc tap water safe to drink?

EPA monitoring detected 20 contaminants in Stucker Mesa Domestic Wc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Stucker Mesa Domestic Wc's water?

EPA monitoring detected Lead, Nitrate, Barium, Fluoride, Selenium, and others. The full list with the level and data source for each is above.

How many people does Stucker Mesa Domestic Wc serve?

Stucker Mesa Domestic Wc reports serving 36 people in Colorado, per its EPA record.

Has Stucker Mesa Domestic Wc had any water quality violations?

The EPA has 538 violations on file for Stucker Mesa Domestic Wc, of which 110 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.