Compliance record
PFAS detected
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 7480.5 µg/L 75% of the EPA limit 10000 µg/L
worst single sample: 8460 µg/L | 640/642 | SYR4 | 2012–2019 |
| Nitrate-Nitrite | 7481 µg/L 75% of the EPA limit 10000 µg/L
worst single sample: 8460 µg/L | 319/320 | SYR4 | 2012–2019 |
| Fluoride | 1518.5 µg/L 38% of the EPA limit 4000 µg/L
worst single sample: 2310 µg/L | 264/264 | SYR4 | 2014–2019 |
| TTHM | 63.86 µg/L 80% of the EPA limit 80 µg/L
worst single sample: 84.38 µg/L | 256/256 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 40.565 µg/L 68% of the EPA limit 60 µg/L
worst single sample: 56.8 µg/L | 251/252 | SYR4 | 2012–2019 |
| Bromodichloromethane | 5.4 µg/L No EPA limit set
worst single sample: 6.3 µg/L | 63/64 | SYR4 | 2012–2018 |
| Dibromochloromethane | 8.995 µg/L No EPA limit set
worst single sample: 11.3 µg/L | 62/64 | SYR4 | 2012–2018 |
| Bromoform | 9.2 µg/L No EPA limit set
worst single sample: 13 µg/L | 61/64 | SYR4 | 2012–2018 |
| Chloroform | 8.05 µg/L No EPA limit set
worst single sample: 1400 µg/L | 55/63 | SYR4 | 2012–2018 |
| Tetrachloroethylene | 1.28 µg/L 26% of the EPA limit 5 µg/L
worst single sample: 1.4 µg/L | 45/486 | SYR4 | 2012–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 21/21 | LCR | 2025 |
| Barium | 91.3 µg/L 4.6% of the EPA limit 2000 µg/L
worst single sample: 97 µg/L | 20/20 | SYR4 | 2014–2017 |
| 1,1-Dichloroethylene | 76.105 µg/L 1087% of the EPA limit, at the 95th percentile of samples — 7 µg/L
worst single sample: 500 µg/L | 18/484 | SYR4 | 2012–2019 |
| Combined Uranium | 20.15 µg/L 67% of the EPA limit 30 µg/L
worst single sample: 21 µg/L | 18/18 | SYR4 | 2012–2017 |
| Picloram | 0.2750 µg/L 0.1% of the EPA limit 500 µg/L
worst single sample: 0.3200 µg/L | 11/62 | SYR4 | 2012–2018 |
| Trichloroethylene | 1 µg/L 20% of the EPA limit 5 µg/L | 11/484 | SYR4 | 2012–2019 |
| Gross Alpha, Excl. Radon And U | 4.6715 pCi/L 31% of the EPA limit 15 pCi/L
worst single sample: 5 pCi/L | 10/18 | SYR4 | 2012–2017 |
| Selenium | 3.64 µg/L 7.3% of the EPA limit 50 µg/L
worst single sample: 4 µg/L | 10/20 | SYR4 | 2014–2017 |
| Lithium | 26.7 µg/L No EPA limit set | 9/12 | UCMR-5 | 2024 |
| cis-1,2-Dichloroethylene | 0.9700 µg/L 1.4% of the EPA limit 70 µg/L
worst single sample: 1 µg/L | 7/483 | SYR4 | 2012–2019 |
| Combined Radium (-226 And -228) | 0.1750 pCi/L 3.5% of the EPA limit 5 pCi/L
worst single sample: 0.2000 pCi/L | 6/7 | SYR4 | 2012 |
| Xylenes, Total | 1.43 µg/L 0% of the EPA limit 10000 µg/L
worst single sample: 1.5 µg/L | 3/485 | SYR4 | 2012–2019 |
| Cadmium | 0.2000 µg/L 4% of the EPA limit 5 µg/L | 1/20 | SYR4 | 2014–2017 |
| Di(2-ethylhexyl) Phthalate | 1.1 µg/L 18% of the EPA limit 6 µg/L | 1/64 | SYR4 | 2012–2019 |
77 contaminants tested, none detected
Utility contact
Frequently asked questions about South Adams County Wsd
Is South Adams County Wsd tap water safe to drink?
EPA monitoring detected 27 contaminants in South Adams County Wsd's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in South Adams County Wsd's water?
EPA monitoring detected Nitrate, Nitrate-Nitrite, Fluoride, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.
How many people does South Adams County Wsd serve?
South Adams County Wsd reports serving 75,559 people in Colorado, per its EPA record.
Has South Adams County Wsd had any water quality violations?
The EPA has no formal drinking-water violations on file for South Adams County Wsd.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.