← California

Tap water quality report

Los Osos Community Services District

EPA monitoring tested this supplier for 92 contaminants and detected 22. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

92
contaminants tested
22
detected
7,086
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
San Luis Obispo

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
3
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2019-10-01
MR Monitoring Resolved 2019-10-01
MR Monitoring Resolved 1993-06-30 → 2000-04-04

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
PFBS 0.0180 µg/L 3/14 2024
Pfhxa 0.0166 µg/L 3/14 2024
PFOA 0.0147 µg/L 3/14 2024
Pfpea 0.0168 µg/L 3/14 2024
Pfhpa 0.0054 µg/L 2/14 2024
Pfba 0.0060 µg/L 1/14 2024
PFHXS 0.0084 µg/L 1/14 2024
PFOS 0.0117 µg/L 1/14 2024

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
14300 µg/L 143%
of the EPA limit, at the 95th percentile of samples — 10000 µg/L
worst single sample: 17600 µg/L
546/592 SYR4 2012–2019
Lead
0.0011 mg/L 7.3%
of the EPA limit 0.0150 mg/L
47/47 LCR 2026
Fluoride
213.5 µg/L 5.3%
of the EPA limit 4000 µg/L
worst single sample: 220 µg/L
14/30 SYR4 2012–2019
Barium
185 µg/L 9.3%
of the EPA limit 2000 µg/L
worst single sample: 190 µg/L
11/19 SYR4 2013–2019
Bromoform
5.66 µg/L
No EPA limit set
worst single sample: 5.8 µg/L
8/8 SYR4 2013–2019
TTHM
7.6 µg/L 9.5%
of the EPA limit 80 µg/L
8/8 SYR4 2013–2019
Dibromoacetic Acid
1.77 µg/L
No EPA limit set
worst single sample: 1.8 µg/L
7/8 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
1.77 µg/L 3%
of the EPA limit 60 µg/L
worst single sample: 1.8 µg/L
7/8 SYR4 2013–2019
Dibromochloromethane
2.475 µg/L
No EPA limit set
worst single sample: 2.5 µg/L
6/8 SYR4 2013–2019
Nitrate-Nitrite
521250 µg/L 5213%
of the EPA limit, at the 95th percentile of samples — 10000 µg/L
worst single sample: 539000 µg/L
6/9 SYR4 2013–2017
Copper
41 µg/L 3.2%
of the EPA limit 1300 µg/L
worst single sample: 44 µg/L
5/23 SYR4 2012–2019
Lithium
16.1 µg/L
No EPA limit set
5/14 UCMR-5 2024
Chromium
33.31 µg/L 33%
of the EPA limit 100 µg/L
worst single sample: 36 µg/L
3/19 SYR4 2013–2019
Lead
6.4 µg/L 43%
of the EPA limit 15 µg/L
1/17 SYR4 2013–2019
70 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneChlorobenzeneCyanideCadmiumCarbon TetrachlorideChloroformDichloromethaneDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDichloroacetic AcidEthylene DibromideEthylbenzeneHexachlorobenzeneHfpo-DaHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaNitritePfdaPfdoaPfeesaPfhpsPfmbaPfmpaPFNAPfpesPftaPftrdaPfunaSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MUNDS, RON
Phone
805-528-9379
Email
[email protected]

Frequently asked questions about Los Osos Community Services District

Is Los Osos Community Services District tap water safe to drink?

EPA monitoring detected 22 contaminants in Los Osos Community Services District's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Los Osos Community Services District's water?

EPA monitoring detected Nitrate, Lead, Fluoride, Barium, Bromoform, and others. The full list with the level and data source for each is above.

How many people does Los Osos Community Services District serve?

Los Osos Community Services District reports serving 7,086 people in California, per its EPA record.

Has Los Osos Community Services District had any water quality violations?

The EPA has 3 violations on file for Los Osos Community Services District, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.