EPA monitoring tested this supplier for 113 contaminants and detected 20. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

113
contaminants tested
20
detected
277,668
people served
0
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
San Diego

Compliance record

No violations on file. The EPA has no formal drinking-water violations recorded for this supplier.

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
14 µg/L
No EPA limit set
worst single sample: 18 µg/L
382/382 SYR4 2012–2019
Dibromochloromethane
19.95 µg/L
No EPA limit set
worst single sample: 26 µg/L
382/382 SYR4 2012–2019
TTHM
48 µg/L 60%
of the EPA limit 80 µg/L
worst single sample: 65 µg/L
381/381 SYR4 2012–2019
Bromoform
12 µg/L
No EPA limit set
worst single sample: 17 µg/L
379/382 SYR4 2012–2019
Chloroform
11 µg/L
No EPA limit set
worst single sample: 22 µg/L
374/382 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
14 µg/L 23%
of the EPA limit 60 µg/L
worst single sample: 23.9 µg/L
350/372 SYR4 2012–2019
Dichloroacetic Acid
7.4 µg/L
No EPA limit set
worst single sample: 17 µg/L
344/372 SYR4 2012–2019
Dibromoacetic Acid
3.9 µg/L
No EPA limit set
worst single sample: 7.1 µg/L
327/372 SYR4 2012–2019
Trichloroacetic Acid
3.7 µg/L
No EPA limit set
worst single sample: 5.8 µg/L
298/372 SYR4 2012–2019
Fluoride
790 µg/L 20%
of the EPA limit 4000 µg/L
worst single sample: 820 µg/L
109/109 SYR4 2012–2019
Nitrate
499.58 µg/L 5%
of the EPA limit 10000 µg/L
worst single sample: 500 µg/L
24/82 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
23/23 LCR 2024
Combined Uranium
10.4196 µg/L 35%
of the EPA limit 30 µg/L
worst single sample: 13.8123 µg/L
19/20 SYR4 2013–2018
Arsenic
3.125 µg/L 31%
of the EPA limit 10 µg/L
worst single sample: 3.2 µg/L
16/27 SYR4 2012–2019
Nitrate-Nitrite
483000 µg/L 4830%
of the EPA limit, at the 95th percentile of samples — 10000 µg/L
worst single sample: 510000 µg/L
10/38 SYR4 2012–2019
Bromate
8.87 µg/L 89%
of the EPA limit 10 µg/L
worst single sample: 9.8 µg/L
7/95 SYR4 2012–2019
Monobromoacetic Acid
1.48 µg/L
No EPA limit set
worst single sample: 1.5 µg/L
5/372 SYR4 2012–2019
Lithium
26 µg/L
No EPA limit set
4/4 UCMR-5 2024
Barium
120 µg/L 6%
of the EPA limit 2000 µg/L
3/27 SYR4 2012–2019
Mercury
1.885 µg/L 94%
of the EPA limit 2 µg/L
worst single sample: 1.9 µg/L
2/26 SYR4 2012–2019
93 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,3,7,8-TCDD2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCopperCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateGross Beta Particle ActivityHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMethoxychlorMonochloroacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
OLNEY, BRIAN
Phone
619-596-1362
Email
[email protected]

Frequently asked questions about Helix Water District

Is Helix Water District tap water safe to drink?

EPA monitoring detected 20 contaminants in Helix Water District's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Helix Water District's water?

EPA monitoring detected Bromodichloromethane, Dibromochloromethane, TTHM, Bromoform, Chloroform, and others. The full list with the level and data source for each is above.

How many people does Helix Water District serve?

Helix Water District reports serving 277,668 people in California, per its EPA record.

Has Helix Water District had any water quality violations?

The EPA has no formal drinking-water violations on file for Helix Water District.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.