Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Unaddressed | 2024-10-17 |
| MCL | Health-based | Resolved | 2017-10-01 → 2017-12-31 |
| MCL | Health-based | Resolved | 2017-10-01 → 2017-12-31 |
| MCL | Health-based | Resolved | 2017-07-01 → 2017-09-30 |
| MCL | Health-based | Resolved | 2017-07-01 → 2017-09-30 |
| MCL | Health-based | Resolved | 2017-04-01 → 2017-06-30 |
| MCL | Health-based | Resolved | 2017-04-01 → 2017-06-30 |
| MCL | Health-based | Resolved | 2014-04-01 → 2014-06-30 |
| MCL | Health-based | Resolved | 2014-04-01 → 2014-06-30 |
| MCL | Health-based | Resolved | 2014-04-01 → 2014-06-30 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 13847.5 µg/L 138% of the EPA limit, at the 95th percentile of samples — 10000 µg/L
worst single sample: 29280 µg/L | 1466/1472 | SYR4 | 2012–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 29/29 | LCR | 2025 |
| Combined Uranium | 8.35294 µg/L 28% of the EPA limit 30 µg/L
worst single sample: 9.089 µg/L | 14/16 | SYR4 | 2014–2019 |
| Bromoform | 10.75 µg/L No EPA limit set
worst single sample: 13 µg/L | 10/17 | SYR4 | 2014–2019 |
| Dibromochloromethane | 5.703 µg/L No EPA limit set
worst single sample: 6 µg/L | 10/17 | SYR4 | 2014–2019 |
| TTHM | 17.931 µg/L 22% of the EPA limit 80 µg/L
worst single sample: 21 µg/L | 10/17 | SYR4 | 2014–2019 |
| Total Haloacetic Acids (HAA5) | 5.695 µg/L 9.5% of the EPA limit 60 µg/L
worst single sample: 6.1 µg/L | 10/13 | SYR4 | 2014–2019 |
| Dibromoacetic Acid | 5.74 µg/L No EPA limit set
worst single sample: 6.1 µg/L | 9/13 | SYR4 | 2014–2019 |
| Fluoride | 1064 µg/L 27% of the EPA limit 4000 µg/L
worst single sample: 1400 µg/L | 9/9 | SYR4 | 2014–2018 |
| Nitrate-Nitrite | 7320 µg/L 73% of the EPA limit 10000 µg/L
worst single sample: 8100 µg/L | 5/6 | SYR4 | 2017–2018 |
| Bromodichloromethane | 3.131 µg/L No EPA limit set
worst single sample: 3.32 µg/L | 4/17 | SYR4 | 2014–2019 |
| Chloroform | 1.4975 µg/L No EPA limit set
worst single sample: 1.51 µg/L | 2/17 | SYR4 | 2014–2019 |
| Trichloroacetic Acid | 1.4 µg/L No EPA limit set | 2/13 | SYR4 | 2014–2019 |
| Arsenic | 2.4 µg/L 24% of the EPA limit 10 µg/L | 1/9 | SYR4 | 2014–2018 |
| Barium | 140 µg/L 7% of the EPA limit 2000 µg/L | 1/9 | SYR4 | 2014–2018 |
| Combined Radium (-226 And -228) | 2 pCi/L 40% of the EPA limit 5 pCi/L | 1/1 | SYR4 | 2018 |
| Dichloroacetic Acid | 1.5 µg/L No EPA limit set | 1/13 | SYR4 | 2014–2019 |
66 contaminants tested, none detected
Utility contact
Frequently asked questions about San Juan Bautista, City of
Is San Juan Bautista, City of tap water safe to drink?
EPA monitoring detected 17 contaminants in San Juan Bautista, City of's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in San Juan Bautista, City of's water?
EPA monitoring detected Nitrate, Lead, Combined Uranium, Bromoform, Dibromochloromethane, and others. The full list with the level and data source for each is above.
How many people does San Juan Bautista, City of serve?
San Juan Bautista, City of reports serving 2,335 people in California, per its EPA record.
Has San Juan Bautista, City of had any water quality violations?
The EPA has 21 violations on file for San Juan Bautista, City of, of which 14 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.