← California

Tap water quality report

Los Madrones Mwc

EPA monitoring tested this supplier for 79 contaminants and detected 21. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

79
contaminants tested
21
detected
36
people served
4
health-based violations
Water source
Ground water
Ownership
Private
Counties served
San Benito

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
48
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 1998-09-01 → 1998-09-30
MCL Health-based Resolved 1998-09-01 → 1998-09-30
MCL Health-based Resolved 1994-09-01 → 1994-09-30
MCL Health-based Resolved 1994-09-01 → 1994-09-30
MR Monitoring Resolved 2016-08-01 → 2016-08-31
MR Monitoring Resolved 2016-08-01 → 2016-08-31
MR Monitoring Resolved 2016-08-01 → 2016-08-31
MR Monitoring Resolved 2016-08-01 → 2016-08-31
MR Monitoring Resolved 2016-08-01 → 2016-08-31
MR Monitoring Resolved 2016-08-01 → 2016-08-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
1130 µg/L 11%
of the EPA limit 10000 µg/L
28/66 SYR4 2012–2019
Combined Uranium
20.86 µg/L 70%
of the EPA limit 30 µg/L
11/11 SYR4 2012–2019
Lead
0.0126 mg/L 84%
of the EPA limit 0.0150 mg/L
9/9 LCR 2023
Chloroform
17.95 µg/L
No EPA limit set
worst single sample: 19 µg/L
8/16 SYR4 2015–2019
TTHM
82.2 µg/L 103%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 85 µg/L
8/16 SYR4 2015–2019
Bromodichloromethane
25.7 µg/L
No EPA limit set
worst single sample: 26 µg/L
7/16 SYR4 2015–2019
Bromoform
33.8 µg/L
No EPA limit set
worst single sample: 38 µg/L
7/16 SYR4 2015–2019
Dibromoacetic Acid
14.7 µg/L
No EPA limit set
worst single sample: 15 µg/L
7/7 SYR4 2017–2019
Dibromochloromethane
26 µg/L
No EPA limit set
7/16 SYR4 2015–2019
Dichloroacetic Acid
15.1 µg/L
No EPA limit set
worst single sample: 16 µg/L
7/7 SYR4 2017–2019
Total Haloacetic Acids (HAA5)
36.7 µg/L 61%
of the EPA limit 60 µg/L
worst single sample: 37 µg/L
7/7 SYR4 2017–2019
Trichloroacetic Acid
7 µg/L
No EPA limit set
7/7 SYR4 2017–2019
Monobromoacetic Acid
2 µg/L
No EPA limit set
6/7 SYR4 2017–2019
Nitrate-Nitrite
500000 µg/L 5000%
of the EPA limit, at the 95th percentile of samples — 10000 µg/L
6/8 SYR4 2013–2019
Fluoride
1280 µg/L 32%
of the EPA limit 4000 µg/L
worst single sample: 1400 µg/L
5/5 SYR4 2013–2019
Arsenic
3.7 µg/L 37%
of the EPA limit 10 µg/L
worst single sample: 4 µg/L
4/5 SYR4 2013–2019
Barium
70.6 µg/L 3.5%
of the EPA limit 2000 µg/L
worst single sample: 73 µg/L
4/5 SYR4 2013–2019
Chromium
30.55 µg/L 31%
of the EPA limit 100 µg/L
worst single sample: 34 µg/L
4/5 SYR4 2013–2019
Nitrite
490 µg/L 49%
of the EPA limit 1000 µg/L
worst single sample: 500 µg/L
3/12 SYR4 2013–2019
Toluene
10.07 µg/L 1%
of the EPA limit 1000 µg/L
worst single sample: 11 µg/L
3/13 SYR4 2012–2019
Selenium
1 µg/L 2%
of the EPA limit 50 µg/L
1/5 SYR4 2013–2019
58 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCopperCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorMonochloroacetic AcidOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
O'MALLEY SOLIS, JESSIE
Phone
408-483-0857
Email
[email protected]

Frequently asked questions about Los Madrones Mwc

Is Los Madrones Mwc tap water safe to drink?

EPA monitoring detected 21 contaminants in Los Madrones Mwc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Los Madrones Mwc's water?

EPA monitoring detected Nitrate, Combined Uranium, Lead, Chloroform, TTHM, and others. The full list with the level and data source for each is above.

How many people does Los Madrones Mwc serve?

Los Madrones Mwc reports serving 36 people in California, per its EPA record.

Has Los Madrones Mwc had any water quality violations?

The EPA has 48 violations on file for Los Madrones Mwc, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.