Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Archived | 1985-08-01 → 1985-08-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 3504.35 µg/L 35% of the EPA limit 10000 µg/L
worst single sample: 4972 µg/L | 118/118 | SYR4 | 2012–2019 |
| Lead | 0.00090 mg/L 6% of the EPA limit 0.0150 mg/L | 70/70 | LCR | 2025 |
| Arsenic | 3.6 µg/L 36% of the EPA limit 10 µg/L
worst single sample: 19 µg/L | 21/34 | SYR4 | 2012–2019 |
| Fluoride | 344 µg/L 8.6% of the EPA limit 4000 µg/L
worst single sample: 380 µg/L | 19/19 | SYR4 | 2012–2019 |
| Combined Uranium | 14.93 µg/L 50% of the EPA limit 30 µg/L
worst single sample: 15 µg/L | 15/15 | SYR4 | 2012–2019 |
| Bromoform | 5.6195 µg/L No EPA limit set
worst single sample: 5.9 µg/L | 12/12 | SYR4 | 2014–2019 |
| TTHM | 13.1635 µg/L 16% of the EPA limit 80 µg/L
worst single sample: 14.83 µg/L | 12/12 | SYR4 | 2014–2019 |
| Lithium | 31.9 µg/L No EPA limit set | 12/12 | UCMR-5 | 2024 |
| Copper | 56.736 µg/L 4.4% of the EPA limit 1300 µg/L
worst single sample: 81 µg/L | 10/125 | SYR4 | 2012–2019 |
| Dibromochloromethane | 5.2865 µg/L No EPA limit set
worst single sample: 5.84 µg/L | 10/12 | SYR4 | 2014–2019 |
| Nitrate-Nitrite | 445400 µg/L 4454% of the EPA limit, at the 95th percentile of samples — 10000 µg/L
worst single sample: 740000 µg/L | 9/9 | SYR4 | 2014–2019 |
| Dibromoacetic Acid | 3.3 µg/L No EPA limit set | 8/12 | SYR4 | 2014–2019 |
| Antimony, Total | 0.0339 µg/L 0.6% of the EPA limit 6 µg/L
worst single sample: 0.0390 µg/L | 7/26 | SYR4 | 2012–2019 |
| Bromodichloromethane | 2.111 µg/L No EPA limit set
worst single sample: 2.42 µg/L | 7/12 | SYR4 | 2014–2019 |
| Cadmium | 0.1302 µg/L 2.6% of the EPA limit 5 µg/L
worst single sample: 0.1590 µg/L | 7/26 | SYR4 | 2012–2019 |
| Lead | 0.2971 µg/L 2% of the EPA limit 15 µg/L
worst single sample: 0.3400 µg/L | 7/111 | SYR4 | 2012–2019 |
| Chromium | 49.855 µg/L 50% of the EPA limit 100 µg/L
worst single sample: 58 µg/L | 4/22 | SYR4 | 2012–2019 |
| Barium | 51.3194 µg/L 2.6% of the EPA limit 2000 µg/L
worst single sample: 52.094 µg/L | 3/22 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 3.3 µg/L 5.5% of the EPA limit 60 µg/L | 3/12 | SYR4 | 2014–2019 |
| Selenium | 5.1589 µg/L 10% of the EPA limit 50 µg/L
worst single sample: 5.221 µg/L | 2/21 | SYR4 | 2012–2019 |
| Chloroform | 0.6700 µg/L No EPA limit set | 1/12 | SYR4 | 2014–2019 |
89 contaminants tested, none detected
Utility contact
Frequently asked questions about Cwsc Salinas Hills
Is Cwsc Salinas Hills tap water safe to drink?
EPA monitoring detected 21 contaminants in Cwsc Salinas Hills's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Cwsc Salinas Hills's water?
EPA monitoring detected Nitrate, Lead, Arsenic, Fluoride, Combined Uranium, and others. The full list with the level and data source for each is above.
How many people does Cwsc Salinas Hills serve?
Cwsc Salinas Hills reports serving 5,293 people in California, per its EPA record.
Has Cwsc Salinas Hills had any water quality violations?
The EPA has 1 violation on file for Cwsc Salinas Hills, of which 1 is health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.