Compliance record
PFAS detected
| Contaminant | Max | Detection rate | Period |
|---|---|---|---|
| Pfba | 0.0056 µg/L | 1/8 | 2024 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| TTHM | 22.1 µg/L 28% of the EPA limit 80 µg/L
worst single sample: 30 µg/L | 94/661 | SYR4 | 2012–2019 |
| Dibromochloromethane | 8.77 µg/L No EPA limit set
worst single sample: 10 µg/L | 55/672 | SYR4 | 2012–2019 |
| Bromodichloromethane | 9.04 µg/L No EPA limit set
worst single sample: 9.4 µg/L | 37/672 | SYR4 | 2012–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 33/33 | LCR | 2023 |
| Bromoform | 3.47 µg/L No EPA limit set
worst single sample: 3.7 µg/L | 27/672 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 12.56 µg/L 21% of the EPA limit 60 µg/L
worst single sample: 16 µg/L | 23/124 | SYR4 | 2012–2019 |
| Chloroform | 9.29 µg/L No EPA limit set
worst single sample: 11 µg/L | 19/672 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 2.62 µg/L No EPA limit set
worst single sample: 2.8 µg/L | 19/124 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 7.765 µg/L No EPA limit set
worst single sample: 8.8 µg/L | 10/124 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 4.4 µg/L No EPA limit set
worst single sample: 4.7 µg/L | 6/124 | SYR4 | 2012–2019 |
| Monochloroacetic Acid | 2.655 µg/L No EPA limit set
worst single sample: 2.7 µg/L | 4/124 | SYR4 | 2012–2019 |
| Lithium | 57 µg/L No EPA limit set | 4/8 | UCMR-5 | 2024 |
| Copper | 190 µg/L 15% of the EPA limit 1300 µg/L | 1/14 | SYR4 | 2012–2019 |
| Lead | 17 µg/L 113% of the EPA limit, at the 95th percentile of samples — 15 µg/L | 1/4 | SYR4 | 2012–2019 |
29 contaminants tested, none detected
Utility contact
Frequently asked questions about Gswc-South San Gabriel
Is Gswc-South San Gabriel tap water safe to drink?
EPA monitoring detected 15 contaminants in Gswc-South San Gabriel's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Gswc-South San Gabriel's water?
EPA monitoring detected TTHM, Dibromochloromethane, Bromodichloromethane, Lead, Bromoform, and others. The full list with the level and data source for each is above.
How many people does Gswc-South San Gabriel serve?
Gswc-South San Gabriel reports serving 26,240 people in California, per its EPA record.
Has Gswc-South San Gabriel had any water quality violations?
The EPA has no formal drinking-water violations on file for Gswc-South San Gabriel.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.