Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MR | Monitoring | Resolved | 2018-02-01 → 2018-03-31 |
| MR | Monitoring | Resolved | 2018-02-01 → 2018-03-31 |
| MR | Monitoring | Resolved | 2014-01-01 → 2014-03-31 |
| MR | Monitoring | Resolved | 2014-01-01 → 2014-03-31 |
| MR | Monitoring | Resolved | 2014-01-01 → 2014-03-31 |
| MR | Monitoring | Resolved | 2014-01-01 → 2014-03-31 |
| MR | Monitoring | Resolved | 2006-01-01 |
| MR | Monitoring | Resolved | 2006-01-01 |
| MR | Monitoring | Resolved | 2003-01-01 |
| MR | Monitoring | Resolved | 2003-01-01 |
PFAS detected
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| TTHM | 37.64 µg/L 47% of the EPA limit 80 µg/L
worst single sample: 51.2 µg/L | 233/256 | SYR4 | 2012–2019 |
| Dibromochloromethane | 13.25 µg/L No EPA limit set
worst single sample: 17.5 µg/L | 231/256 | SYR4 | 2012–2019 |
| Bromoform | 6.94 µg/L No EPA limit set
worst single sample: 11.6 µg/L | 213/256 | SYR4 | 2012–2019 |
| Bromodichloromethane | 11.6 µg/L No EPA limit set
worst single sample: 15.6 µg/L | 172/256 | SYR4 | 2012–2019 |
| Tetrachloroethylene | 4.255 µg/L 85% of the EPA limit 5 µg/L
worst single sample: 7.4 µg/L | 150/178 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 13.21 µg/L 22% of the EPA limit 60 µg/L
worst single sample: 18 µg/L | 88/248 | SYR4 | 2012–2019 |
| Chloroform | 10.835 µg/L No EPA limit set
worst single sample: 15.2 µg/L | 84/255 | SYR4 | 2012–2019 |
| Nitrate | 2000 µg/L 20% of the EPA limit 10000 µg/L
worst single sample: 2400 µg/L | 82/88 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 4.725 µg/L No EPA limit set
worst single sample: 6.3 µg/L | 80/248 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 6.96 µg/L No EPA limit set
worst single sample: 7.9 µg/L | 53/248 | SYR4 | 2012–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 38/38 | LCR | 2024 |
| Trichloroethylene | 6.24 µg/L 125% of the EPA limit, at the 95th percentile of samples — 5 µg/L
worst single sample: 6.9 µg/L | 25/64 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 4.1 µg/L No EPA limit set
worst single sample: 4.2 µg/L | 21/248 | SYR4 | 2012–2019 |
| Fluoride | 400 µg/L 10% of the EPA limit 4000 µg/L | 17/17 | SYR4 | 2012–2019 |
| Arsenic | 4.87 µg/L 49% of the EPA limit 10 µg/L
worst single sample: 5 µg/L | 14/14 | SYR4 | 2012–2019 |
| Barium | 143.5 µg/L 7.2% of the EPA limit 2000 µg/L
worst single sample: 150 µg/L | 14/14 | SYR4 | 2012–2019 |
| Combined Uranium | 6.42935 µg/L 21% of the EPA limit 30 µg/L
worst single sample: 7.003 µg/L | 8/9 | SYR4 | 2012–2018 |
| Lithium | 49 µg/L No EPA limit set | 4/14 | UCMR-5 | 2025 |
| 1,1-Dichloroethylene | 0.6200 µg/L 8.9% of the EPA limit 7 µg/L | 1/46 | SYR4 | 2012–2019 |
| Copper | 210 µg/L 16% of the EPA limit 1300 µg/L | 1/24 | SYR4 | 2012–2019 |
| Chromium | 12 µg/L 12% of the EPA limit 100 µg/L | 1/14 | SYR4 | 2012–2019 |
| Nitrate-Nitrite | 730000 µg/L 7300% of the EPA limit, at the 95th percentile of samples — 10000 µg/L | 1/1 | SYR4 | 2012 |
85 contaminants tested, none detected
Utility contact
Frequently asked questions about Lynwood-City, Water Dept.
Is Lynwood-City, Water Dept. tap water safe to drink?
EPA monitoring detected 26 contaminants in Lynwood-City, Water Dept.'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Lynwood-City, Water Dept.'s water?
EPA monitoring detected TTHM, Dibromochloromethane, Bromoform, Bromodichloromethane, Tetrachloroethylene, and others. The full list with the level and data source for each is above.
How many people does Lynwood-City, Water Dept. serve?
Lynwood-City, Water Dept. reports serving 66,967 people in California, per its EPA record.
Has Lynwood-City, Water Dept. had any water quality violations?
The EPA has 13 violations on file for Lynwood-City, Water Dept., of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.