← California

Tap water quality report

Gswc - Florence/Graham

EPA monitoring tested this supplier for 110 contaminants and detected 27. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

110
contaminants tested
27
detected
63,472
people served
0
health-based violations
Water source
SWP
Ownership
Private
Counties served
Los Angeles

Compliance record

No violations on file. The EPA has no formal drinking-water violations recorded for this supplier.

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Trichloroethylene
39 µg/L 780%
of the EPA limit, at the 95th percentile of samples — 5 µg/L
worst single sample: 84 µg/L
1338/3489 SYR4 2012–2019
Carbon Tetrachloride
2.77 µg/L 55%
of the EPA limit 5 µg/L
worst single sample: 4 µg/L
467/2811 SYR4 2012–2019
1,2-Dichloroethane
2.1 µg/L 42%
of the EPA limit 5 µg/L
worst single sample: 2.5 µg/L
277/1524 SYR4 2012–2019
Nitrate
7235 µg/L 72%
of the EPA limit 10000 µg/L
worst single sample: 7800 µg/L
154/164 SYR4 2012–2019
TTHM
48 µg/L 60%
of the EPA limit 80 µg/L
worst single sample: 55 µg/L
134/168 SYR4 2012–2019
cis-1,2-Dichloroethylene
4.39 µg/L 6.3%
of the EPA limit 70 µg/L
worst single sample: 7.3 µg/L
123/440 SYR4 2012–2019
Tetrachloroethylene
8.32 µg/L 166%
of the EPA limit, at the 95th percentile of samples — 5 µg/L
worst single sample: 9.7 µg/L
109/1169 SYR4 2012–2019
Bromoform
8.9 µg/L
No EPA limit set
worst single sample: 26 µg/L
101/169 SYR4 2012–2019
Dibromochloromethane
16.35 µg/L
No EPA limit set
worst single sample: 20 µg/L
74/169 SYR4 2012–2019
Dibromoacetic Acid
4.715 µg/L
No EPA limit set
worst single sample: 5.8 µg/L
60/156 SYR4 2012–2019
Fluoride
526 µg/L 13%
of the EPA limit 4000 µg/L
worst single sample: 700 µg/L
55/55 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
23.35 µg/L 39%
of the EPA limit 60 µg/L
worst single sample: 25 µg/L
54/156 SYR4 2012–2019
Bromodichloromethane
15.65 µg/L
No EPA limit set
worst single sample: 17 µg/L
48/169 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
40/40 LCR 2025
Chloroform
17.4 µg/L
No EPA limit set
worst single sample: 19 µg/L
33/169 SYR4 2012–2019
Dichloroacetic Acid
9.04 µg/L
No EPA limit set
worst single sample: 10 µg/L
30/156 SYR4 2012–2019
Monochloroacetic Acid
4.96 µg/L
No EPA limit set
worst single sample: 5.2 µg/L
29/156 SYR4 2012–2019
Trichloroacetic Acid
7.24 µg/L
No EPA limit set
worst single sample: 7.4 µg/L
24/156 SYR4 2012–2019
Barium
130 µg/L 6.5%
of the EPA limit 2000 µg/L
18/21 SYR4 2012–2018
Combined Uranium
11.6518 µg/L 39%
of the EPA limit 30 µg/L
worst single sample: 12.069 µg/L
15/15 SYR4 2012–2018
Nitrate-Nitrite
385000 µg/L 3850%
of the EPA limit, at the 95th percentile of samples — 10000 µg/L
worst single sample: 400000 µg/L
11/11 SYR4 2012–2018
Monobromoacetic Acid
3.72 µg/L
No EPA limit set
worst single sample: 3.8 µg/L
9/156 SYR4 2012–2019
Selenium
7.56 µg/L 15%
of the EPA limit 50 µg/L
worst single sample: 8.1 µg/L
7/21 SYR4 2012–2018
Lithium
45 µg/L
No EPA limit set
4/8 UCMR-5 2024
Lead
8.23 µg/L 55%
of the EPA limit 15 µg/L
worst single sample: 8.4 µg/L
2/21 SYR4 2012–2018
Copper
76 µg/L 5.8%
of the EPA limit 1300 µg/L
1/21 SYR4 2012–2018
Chromium
2.5 µg/L 2.5%
of the EPA limit 100 µg/L
1/21 SYR4 2012–2018
83 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloropropane11Cl-PF3OUdS2,3,7,8-TCDD2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneVinyl ChlorideXylenes, TotalO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
FLORES, ROCIO
Phone
626-250-1517
Email
[email protected]

Frequently asked questions about Gswc - Florence/Graham

Is Gswc - Florence/Graham tap water safe to drink?

EPA monitoring detected 27 contaminants in Gswc - Florence/Graham's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Gswc - Florence/Graham's water?

EPA monitoring detected Trichloroethylene, Carbon Tetrachloride, 1,2-Dichloroethane, Nitrate, TTHM, and others. The full list with the level and data source for each is above.

How many people does Gswc - Florence/Graham serve?

Gswc - Florence/Graham reports serving 63,472 people in California, per its EPA record.

Has Gswc - Florence/Graham had any water quality violations?

The EPA has no formal drinking-water violations on file for Gswc - Florence/Graham.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.