Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2009-06-01 → 2009-06-30 |
| MCL | Health-based | Resolved | 2009-06-01 → 2009-06-30 |
| MCL | Health-based | Resolved | 2006-02-01 → 2006-02-28 |
| MCL | Health-based | Resolved | 2006-02-01 → 2006-02-28 |
| MCL | Health-based | Resolved | 1996-09-16 → 1997-05-07 |
| MCL | Health-based | Resolved | 1996-09-16 → 1997-05-07 |
PFAS detected
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| TTHM | 44.425 µg/L 56% of the EPA limit 80 µg/L
worst single sample: 56.1 µg/L | 44/65 | SYR4 | 2012–2019 |
| Bromoform | 5.01 µg/L No EPA limit set
worst single sample: 5.6 µg/L | 39/65 | SYR4 | 2012–2019 |
| Dibromochloromethane | 15.22 µg/L No EPA limit set
worst single sample: 19.8 µg/L | 35/65 | SYR4 | 2012–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 29/29 | LCR | 2024 |
| Nitrate | 990 µg/L 9.9% of the EPA limit 10000 µg/L | 20/26 | SYR4 | 2012–2019 |
| Fluoride | 910 µg/L 23% of the EPA limit 4000 µg/L | 12/12 | SYR4 | 2012–2019 |
| Combined Uranium | 3.725 µg/L 12% of the EPA limit 30 µg/L | 8/8 | SYR4 | 2012–2019 |
| Bromodichloromethane | 16.025 µg/L No EPA limit set
worst single sample: 16.7 µg/L | 6/65 | SYR4 | 2012–2019 |
| Barium | 172 µg/L 8.6% of the EPA limit 2000 µg/L
worst single sample: 180 µg/L | 5/6 | SYR4 | 2012–2017 |
| Dibromoacetic Acid | 6 µg/L No EPA limit set
worst single sample: 6.2 µg/L | 5/62 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 20.12 µg/L 34% of the EPA limit 60 µg/L
worst single sample: 20.7 µg/L | 5/62 | SYR4 | 2012–2019 |
| Arsenic | 4.37 µg/L 44% of the EPA limit 10 µg/L
worst single sample: 4.4 µg/L | 4/6 | SYR4 | 2012–2017 |
| Chloroform | 14.34 µg/L No EPA limit set
worst single sample: 14.4 µg/L | 4/65 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 8.955 µg/L No EPA limit set
worst single sample: 9 µg/L | 4/62 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 5.425 µg/L No EPA limit set
worst single sample: 5.5 µg/L | 4/62 | SYR4 | 2012–2019 |
| Nitrate-Nitrite | 740000 µg/L 7400% of the EPA limit, at the 95th percentile of samples — 10000 µg/L | 1/4 | SYR4 | 2012 |
91 contaminants tested, none detected
Utility contact
Frequently asked questions about Bellflower Municipal Water
Is Bellflower Municipal Water tap water safe to drink?
EPA monitoring detected 20 contaminants in Bellflower Municipal Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Bellflower Municipal Water's water?
EPA monitoring detected TTHM, Bromoform, Dibromochloromethane, Lead, Nitrate, and others. The full list with the level and data source for each is above.
How many people does Bellflower Municipal Water serve?
Bellflower Municipal Water reports serving 5,999 people in California, per its EPA record.
Has Bellflower Municipal Water had any water quality violations?
The EPA has 6 violations on file for Bellflower Municipal Water, of which 6 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?