Compliance record
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Bromodichloromethane | 16.4 µg/L No EPA limit set
worst single sample: 32.7 µg/L | 271/272 | SYR4 | 2012–2019 |
| TTHM | 65.4 µg/L 82% of the EPA limit 80 µg/L
worst single sample: 86 µg/L | 271/272 | SYR4 | 2012–2019 |
| Chloroform | 50.4 µg/L No EPA limit set
worst single sample: 67.3 µg/L | 270/272 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 35.2 µg/L No EPA limit set
worst single sample: 46.9 µg/L | 256/256 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 69.525 µg/L 116% of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 91.4 µg/L | 256/256 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 34.08 µg/L No EPA limit set
worst single sample: 51.5 µg/L | 242/256 | SYR4 | 2012–2019 |
| Nitrate | 1989.37 µg/L 20% of the EPA limit 10000 µg/L
worst single sample: 2915.4 µg/L | 226/528 | SYR4 | 2012–2019 |
| Dibromochloromethane | 20.65 µg/L No EPA limit set
worst single sample: 25.1 µg/L | 183/272 | SYR4 | 2012–2019 |
| Fluoride | 310 µg/L 7.8% of the EPA limit 4000 µg/L
worst single sample: 1600 µg/L | 174/259 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 5.4 µg/L No EPA limit set
worst single sample: 6.3 µg/L | 128/256 | SYR4 | 2012–2019 |
| Bromoform | 6.82 µg/L No EPA limit set
worst single sample: 9.5 µg/L | 115/272 | SYR4 | 2012–2019 |
| Arsenic | 8.581 µg/L 86% of the EPA limit 10 µg/L
worst single sample: 11.4 µg/L | 103/168 | SYR4 | 2012–2019 |
| Nitrate-Nitrite | 750500 µg/L 7505% of the EPA limit, at the 95th percentile of samples — 10000 µg/L
worst single sample: 979000 µg/L | 75/198 | SYR4 | 2012–2019 |
| Monochloroacetic Acid | 2.4 µg/L No EPA limit set
worst single sample: 2.9 µg/L | 50/256 | SYR4 | 2012–2019 |
| Chromium | 3.2315 µg/L 3.2% of the EPA limit 100 µg/L
worst single sample: 4.51 µg/L | 34/166 | SYR4 | 2012–2019 |
| Monobromoacetic Acid | 13.575 µg/L No EPA limit set
worst single sample: 15.8 µg/L | 26/256 | SYR4 | 2012–2019 |
| Combined Uranium | 7.6884 µg/L 26% of the EPA limit 30 µg/L
worst single sample: 8.344 µg/L | 9/10 | SYR4 | 2012–2014 |
| 1,2-DIBROMO-3-CHLOROPROPANE | 0.0128 µg/L 6.4% of the EPA limit 0.2000 µg/L
worst single sample: 0.0130 µg/L | 5/145 | SYR4 | 2012–2019 |
| Lead | 17.94 µg/L 120% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 18.3 µg/L | 3/146 | SYR4 | 2012–2019 |
| Copper | 53.7 µg/L 4.1% of the EPA limit 1300 µg/L
worst single sample: 53.9 µg/L | 2/259 | SYR4 | 2012–2019 |
| Toluene | 1.175 µg/L 0.1% of the EPA limit 1000 µg/L
worst single sample: 1.2 µg/L | 2/160 | SYR4 | 2012–2019 |
| Barium | 129 µg/L 6.5% of the EPA limit 2000 µg/L | 1/150 | SYR4 | 2012–2019 |
| Ethylene Dibromide | 0.0190 µg/L 38% of the EPA limit 0.0500 µg/L | 1/145 | SYR4 | 2012–2019 |
| Glyphosate | 32 µg/L 4.6% of the EPA limit 700 µg/L | 1/44 | SYR4 | 2012–2019 |
| Heptachlor | 0.0100 µg/L 2.5% of the EPA limit 0.4000 µg/L | 1/117 | SYR4 | 2012–2019 |
56 contaminants tested, none detected
Utility contact
Frequently asked questions about Kern County Water Agency
Is Kern County Water Agency tap water safe to drink?
EPA monitoring detected 25 contaminants in Kern County Water Agency's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Kern County Water Agency's water?
EPA monitoring detected Bromodichloromethane, TTHM, Chloroform, Dichloroacetic Acid, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.
How many people does Kern County Water Agency serve?
Kern County Water Agency reports serving 0 people in California, per its EPA record.
Has Kern County Water Agency had any water quality violations?
The EPA has no formal drinking-water violations on file for Kern County Water Agency.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.