← California

Tap water quality report

Ione Band of Miwok Indians

EPA monitoring tested this supplier for 50 contaminants and detected 13. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

50
contaminants tested
13
detected
40
people served
3
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Amador

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

3
health-based violations
9
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2006-07-01 → 2006-07-31
MCL Health-based Resolved 2006-07-01 → 2006-07-31
MCL Health-based Resolved 2006-07-01 → 2006-07-31
MR Monitoring Resolved 2022-10-01
MR Monitoring Resolved 2022-10-01
MR Monitoring Resolved 2013-10-01
MR Monitoring Resolved 2013-10-01
MR Monitoring Resolved 2006-09-01 → 2006-09-30
MR Monitoring Resolved 2006-09-01 → 2006-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
118.175 µg/L
No EPA limit set
worst single sample: 121.2 µg/L
6/9 SYR4 2015–2019
Bromoform
50.2525 µg/L
No EPA limit set
worst single sample: 61.37 µg/L
6/8 SYR4 2017–2019
Dibromochloromethane
35.825 µg/L
No EPA limit set
worst single sample: 38.65 µg/L
6/9 SYR4 2015–2019
TTHM
310.155 µg/L 388%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 314.29 µg/L
6/8 SYR4 2017–2019
Total Haloacetic Acids (HAA5)
174.05 µg/L 290%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 194.9 µg/L
6/8 SYR4 2017–2019
Chloroform
164.16 µg/L
No EPA limit set
worst single sample: 173.1 µg/L
5/9 SYR4 2015–2019
Dibromoacetic Acid
22.48 µg/L
No EPA limit set
worst single sample: 24 µg/L
5/8 SYR4 2017–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
4/4 LCR 2023
Trichloroacetic Acid
7.015 µg/L
No EPA limit set
worst single sample: 7.6 µg/L
4/9 SYR4 2015–2019
Dichloroacetic Acid
111.14 µg/L
No EPA limit set
worst single sample: 114.6 µg/L
3/9 SYR4 2015–2019
Monobromoacetic Acid
3.77 µg/L
No EPA limit set
worst single sample: 3.8 µg/L
3/9 SYR4 2015–2019
Fluoride
395 µg/L 9.9%
of the EPA limit 4000 µg/L
worst single sample: 400 µg/L
2/2 SYR4 2014–2016
Monochloroacetic Acid
53 µg/L
No EPA limit set
1/9 SYR4 2015–2019
37 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-DichloropropaneAntimony, TotalArsenicAsbestosAtrazineBariumBenzeneBeryllium, TotalChlorobenzeneCopperCadmiumCarbon TetrachlorideChromiumDichloromethaneEthylbenzeneMercuryNitrateNitrate-NitriteNitriteSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
SCHINKO, STACEY
Phone
209-253-1743
Email
[email protected]

Frequently asked questions about Ione Band of Miwok Indians

Is Ione Band of Miwok Indians tap water safe to drink?

EPA monitoring detected 13 contaminants in Ione Band of Miwok Indians's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Ione Band of Miwok Indians's water?

EPA monitoring detected Bromodichloromethane, Bromoform, Dibromochloromethane, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does Ione Band of Miwok Indians serve?

Ione Band of Miwok Indians reports serving 40 people in California, per its EPA record.

Has Ione Band of Miwok Indians had any water quality violations?

The EPA has 9 violations on file for Ione Band of Miwok Indians, of which 3 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.