← Arizona

Tap water quality report

Sedona Venture Water Company

EPA monitoring tested this supplier for 80 contaminants and detected 15. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

80
contaminants tested
15
detected
480
people served
11
health-based violations
Water source
Ground water
Ownership
Mixed public/private
Counties served
Yavapai

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

11
health-based violations
105
violations on file
1
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2009-07-01 → 2009-09-30
MCL Health-based Resolved 2009-04-01 → 2009-06-30
MCL Health-based Resolved 2009-01-01 → 2009-03-31
MCL Health-based Resolved 2008-10-01 → 2008-12-31
MCL Health-based Resolved 2008-07-01 → 2008-09-30
MCL Health-based Resolved 2008-07-01 → 2008-09-30
MCL Health-based Resolved 2008-04-01 → 2008-06-30
MCL Health-based Resolved 2007-10-01 → 2007-12-31
MCL Health-based Resolved 2007-10-01 → 2007-12-31
MCL Health-based Resolved 2007-10-01 → 2007-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
88 µg/L 6.8%
of the EPA limit 1300 µg/L
worst single sample: 504 µg/L
45/90 SYR4 2012–2019
Arsenic
10.715 µg/L 107%
of the EPA limit, at the 95th percentile of samples — 10 µg/L
worst single sample: 11.4 µg/L
22/37 SYR4 2012–2019
Lead
80.04 µg/L 534%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 163 µg/L
18/90 SYR4 2012–2019
Nitrate
520 µg/L 5.2%
of the EPA limit 10000 µg/L
18/18 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
17/17 LCR 2026
TTHM
3.99 µg/L 5%
of the EPA limit 80 µg/L
worst single sample: 4.2 µg/L
7/8 SYR4 2012–2019
Barium
179 µg/L 9%
of the EPA limit 2000 µg/L
worst single sample: 180 µg/L
2/2 SYR4 2012–2018
Chromium
2.085 µg/L 2.1%
of the EPA limit 100 µg/L
worst single sample: 2.1 µg/L
2/2 SYR4 2012–2018
Fluoride
99.6 µg/L 2.5%
of the EPA limit 4000 µg/L
worst single sample: 100 µg/L
2/2 SYR4 2012–2018
Nitrate-Nitrite
466.5 µg/L 4.7%
of the EPA limit 10000 µg/L
worst single sample: 470 µg/L
2/2 SYR4 2012
Bromodichloromethane
0.5000 µg/L
No EPA limit set
1/1 SYR4 2019
Bromoform
1.5 µg/L
No EPA limit set
1/1 SYR4 2019
Dibromoacetic Acid
1.3 µg/L
No EPA limit set
1/1 SYR4 2019
Dibromochloromethane
1.4 µg/L
No EPA limit set
1/1 SYR4 2019
Total Haloacetic Acids (HAA5)
1.3 µg/L 2.2%
of the EPA limit 60 µg/L
1/8 SYR4 2012–2019
65 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformCombined Radium (-226 And -228)DichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDichloroacetic AcidDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
EQUITY LIFESTYLE PROPERTIES
Phone
312-279-1400
Email
[email protected]

Frequently asked questions about Sedona Venture Water Company

Is Sedona Venture Water Company tap water safe to drink?

EPA monitoring detected 15 contaminants in Sedona Venture Water Company's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Sedona Venture Water Company's water?

EPA monitoring detected Copper, Arsenic, Lead, Nitrate, Lead, and others. The full list with the level and data source for each is above.

How many people does Sedona Venture Water Company serve?

Sedona Venture Water Company reports serving 480 people in Arizona, per its EPA record.

Has Sedona Venture Water Company had any water quality violations?

The EPA has 105 violations on file for Sedona Venture Water Company, of which 11 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.