← Arizona

Tap water quality report

Arizona Water Co - Lakeside

EPA monitoring tested this supplier for 101 contaminants and detected 15. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

101
contaminants tested
15
detected
12,191
people served
0
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Navajo

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
84
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2015-10-01 → 2015-12-31
MR Monitoring Resolved 2008-01-01 → 2008-12-31
MR Monitoring Resolved 2008-01-01 → 2008-12-31
MR Monitoring Resolved 2008-01-01 → 2008-12-31
MR Monitoring Resolved 2008-01-01 → 2008-12-31
MR Monitoring Resolved 2008-01-01 → 2008-12-31
MR Monitoring Resolved 2008-01-01 → 2008-12-31
MR Monitoring Resolved 2008-01-01 → 2008-12-31
MR Monitoring Resolved 2008-01-01 → 2008-12-31
MR Monitoring Resolved 2008-01-01 → 2008-12-31

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
PFBS 0.0034 µg/L 1/10 2025

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
8.55 µg/L 11%
of the EPA limit 80 µg/L
worst single sample: 15.4 µg/L
106/110 SYR4 2012–2019
Copper
208.2 µg/L 16%
of the EPA limit 1300 µg/L
worst single sample: 390 µg/L
93/94 SYR4 2013–2019
Lead
9.45 µg/L 63%
of the EPA limit 15 µg/L
worst single sample: 30.2 µg/L
50/94 SYR4 2013–2019
Nitrate
1332.5 µg/L 13%
of the EPA limit 10000 µg/L
worst single sample: 1340 µg/L
26/80 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
3.5 µg/L 5.8%
of the EPA limit 60 µg/L
worst single sample: 4.3 µg/L
21/108 SYR4 2012–2019
Nitrate-Nitrite
1325 µg/L 13%
of the EPA limit 10000 µg/L
worst single sample: 1340 µg/L
11/34 SYR4 2012–2018
Lead
0.0078 mg/L 52%
of the EPA limit 0.0150 mg/L
10/10 LCR 2025
Arsenic
3.04 µg/L 30%
of the EPA limit 10 µg/L
worst single sample: 3.4 µg/L
7/7 SYR4 2012–2015
Barium
230 µg/L 12%
of the EPA limit 2000 µg/L
worst single sample: 290 µg/L
7/7 SYR4 2012–2015
Selenium
7.25 µg/L 14%
of the EPA limit 50 µg/L
worst single sample: 8 µg/L
6/7 SYR4 2012–2015
Lithium
25.1 µg/L
No EPA limit set
6/10 UCMR-5 2025
Fluoride
178.5 µg/L 4.5%
of the EPA limit 4000 µg/L
worst single sample: 180 µg/L
4/7 SYR4 2012–2015
Combined Radium (-226 And -228)
1.78 pCi/L 36%
of the EPA limit 5 pCi/L
worst single sample: 1.8 pCi/L
3/4 SYR4 2012–2015
Endrin
0.0100 µg/L 0.5%
of the EPA limit 2 µg/L
1/22 SYR4 2012–2018
86 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,3,7,8-TCDD2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
CAVALIER, RYAN
Phone
602-294-2151
Email
[email protected]

Frequently asked questions about Arizona Water Co - Lakeside

Is Arizona Water Co - Lakeside tap water safe to drink?

EPA monitoring detected 15 contaminants in Arizona Water Co - Lakeside's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Arizona Water Co - Lakeside's water?

EPA monitoring detected TTHM, Copper, Lead, Nitrate, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does Arizona Water Co - Lakeside serve?

Arizona Water Co - Lakeside reports serving 12,191 people in Arizona, per its EPA record.

Has Arizona Water Co - Lakeside had any water quality violations?

The EPA has 84 violations on file for Arizona Water Co - Lakeside, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.