← Arizona

Tap water quality report

Aspc Lewis Complex Water

EPA monitoring tested this supplier for 103 contaminants and detected 19. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

103
contaminants tested
19
detected
4,300
people served
16
health-based violations
Water source
Ground water
Ownership
State government
Counties served
Maricopa

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

16
health-based violations
567
violations on file
5
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2022-04-01
TT Health-based Resolved 2022-04-01
TT Health-based Resolved 2022-04-01
TT Health-based Resolved 2022-04-01
TT Health-based Resolved 2022-04-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
178.2 µg/L 14%
of the EPA limit 1300 µg/L
worst single sample: 642 µg/L
37/40 SYR4 2014–2017
Lead
0.0023 mg/L 15%
of the EPA limit 0.0150 mg/L
20/20 LCR 2025
Nitrate
630 µg/L 6.3%
of the EPA limit 10000 µg/L
18/18 SYR4 2012–2019
Lead
45.6 µg/L 304%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 71.5 µg/L
11/40 SYR4 2014–2017
TTHM
10.24 µg/L 13%
of the EPA limit 80 µg/L
worst single sample: 11 µg/L
9/12 SYR4 2012–2019
Nitrate-Nitrite
621.15 µg/L 6.2%
of the EPA limit 10000 µg/L
worst single sample: 630 µg/L
4/4 SYR4 2012–2017
Barium
5.783 µg/L 0.3%
of the EPA limit 2000 µg/L
worst single sample: 5.83 µg/L
3/3 SYR4 2012–2017
Fluoride
2571 µg/L 64%
of the EPA limit 4000 µg/L
worst single sample: 2600 µg/L
3/3 SYR4 2012–2017
Total Haloacetic Acids (HAA5)
4.6195 µg/L 7.7%
of the EPA limit 60 µg/L
worst single sample: 4.66 µg/L
2/12 SYR4 2012–2019
Lithium
281 µg/L
No EPA limit set
2/2 UCMR-5 2024
Atrazine
0.5000 µg/L 17%
of the EPA limit 3 µg/L
1/7 SYR4 2013–2018
Benzo(A)Pyrene
0.1000 µg/L 50%
of the EPA limit 0.2000 µg/L
1/7 SYR4 2013–2018
Combined Radium (-226 And -228)
0.3000 pCi/L 6%
of the EPA limit 5 pCi/L
1/3 SYR4 2016–2018
Di(2-ethylhexyl) Adipate
5 µg/L 1.3%
of the EPA limit 400 µg/L
1/7 SYR4 2013–2018
Di(2-ethylhexyl) Phthalate
0.1000 µg/L 1.7%
of the EPA limit 6 µg/L
1/7 SYR4 2013–2018
Gross Alpha, Excl. Radon And U
1.2 pCi/L 8%
of the EPA limit 15 pCi/L
1/1 SYR4 2018
Hexachlorobenzene
0.5000 µg/L 50%
of the EPA limit 1 µg/L
1/7 SYR4 2013–2018
Hexachlorocyclopentadiene
1 µg/L 2%
of the EPA limit 50 µg/L
1/7 SYR4 2013–2018
Simazine
1 µg/L 25%
of the EPA limit 4 µg/L
1/7 SYR4 2013–2018
84 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,3,7,8-TCDD2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAsbestosBhc-GammaBenzeneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHfpo-DaHeptachlorHeptachlor EpoxideLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
KENNEY, CHRISTOPHER
Phone
623-386-6160
Email
[email protected]

Frequently asked questions about Aspc Lewis Complex Water

Is Aspc Lewis Complex Water tap water safe to drink?

EPA monitoring detected 19 contaminants in Aspc Lewis Complex Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Aspc Lewis Complex Water's water?

EPA monitoring detected Copper, Lead, Nitrate, Lead, TTHM, and others. The full list with the level and data source for each is above.

How many people does Aspc Lewis Complex Water serve?

Aspc Lewis Complex Water reports serving 4,300 people in Arizona, per its EPA record.

Has Aspc Lewis Complex Water had any water quality violations?

The EPA has 567 violations on file for Aspc Lewis Complex Water, of which 16 are health-based (a contaminant limit or required treatment was breached) and 5 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.