← Arizona

Tap water quality report

Beardsley Water Company 1

EPA monitoring tested this supplier for 98 contaminants and detected 10. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

98
contaminants tested
10
detected
10,263
people served
0
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Maricopa

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
79
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2024-04-01 → 2024-04-30
MR Monitoring Resolved 2024-04-01 → 2024-04-30
RPT Monitoring Resolved 2022-05-01
RPT Monitoring Resolved 2022-05-01
MR Monitoring Resolved 2021-10-01 → 2021-12-31
MR Monitoring Resolved 2021-10-01 → 2021-12-31
RPT Monitoring Resolved 2021-05-01
RPT Monitoring Resolved 2021-05-01
MR Monitoring Resolved 2020-10-01
MR Monitoring Resolved 2020-10-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
1300 µg/L 13%
of the EPA limit 10000 µg/L
36/36 SYR4 2012–2019
Copper
167.5 µg/L 13%
of the EPA limit 1300 µg/L
worst single sample: 260 µg/L
26/37 SYR4 2013–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
13/13 LCR 2024
Lead
18.85 µg/L 126%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 22 µg/L
10/37 SYR4 2013–2019
Lithium
19 µg/L
No EPA limit set
6/6 UCMR-5 2024
2,4-D
0.3200 µg/L 0.5%
of the EPA limit 70 µg/L
2/2 SYR4 2017
Arsenic
3.94 µg/L 39%
of the EPA limit 10 µg/L
worst single sample: 4 µg/L
2/2 SYR4 2017
Barium
84.25 µg/L 4.2%
of the EPA limit 2000 µg/L
worst single sample: 85 µg/L
2/2 SYR4 2017
Chromium
20 µg/L 20%
of the EPA limit 100 µg/L
2/2 SYR4 2017
Fluoride
638 µg/L 16%
of the EPA limit 4000 µg/L
worst single sample: 640 µg/L
2/2 SYR4 2017
88 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,3,7,8-TCDD2,4,5-TP4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined Radium (-226 And -228)DichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTTHMTetrachloroethyleneThallium, TotalTolueneTotal Haloacetic Acids (HAA5)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
FRIEDMAN, PAUL
Phone
623-935-9367
Email
[email protected]

Frequently asked questions about Beardsley Water Company 1

Is Beardsley Water Company 1 tap water safe to drink?

EPA monitoring detected 10 contaminants in Beardsley Water Company 1's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Beardsley Water Company 1's water?

EPA monitoring detected Nitrate, Copper, Lead, Lead, Lithium, and others. The full list with the level and data source for each is above.

How many people does Beardsley Water Company 1 serve?

Beardsley Water Company 1 reports serving 10,263 people in Arizona, per its EPA record.

Has Beardsley Water Company 1 had any water quality violations?

The EPA has 79 violations on file for Beardsley Water Company 1, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.