← Arizona

Tap water quality report

Glen Canyon Nra Wahweap

EPA monitoring tested this supplier for 106 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

106
contaminants tested
18
detected
579
people served
5
health-based violations
Water source
Ground water
Ownership
Federal government
Counties served
Coconino

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

5
health-based violations
385
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
MCL Health-based Archived 1988-07-01 → 1988-09-30
MR Monitoring Archived 2026-01-01 → 2026-01-31
MR Monitoring Archived 2025-10-01 → 2025-12-31
MR Monitoring Archived 2025-10-01 → 2025-12-31
MR Monitoring Archived 2025-10-01 → 2025-12-31
MR Monitoring Archived 2025-10-01 → 2025-12-31

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Pfba 0.0054 µg/L 1/2 2023

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
194 µg/L 15%
of the EPA limit 1300 µg/L
worst single sample: 3000 µg/L
27/31 SYR4 2013–2017
TTHM
52.825 µg/L 66%
of the EPA limit 80 µg/L
worst single sample: 63.7 µg/L
16/16 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
9.973 µg/L 17%
of the EPA limit 60 µg/L
worst single sample: 11.8 µg/L
15/15 SYR4 2012–2019
Lead
0.0057 mg/L 38%
of the EPA limit 0.0150 mg/L
13/13 LCR 2026
Lead
6.885 µg/L 46%
of the EPA limit 15 µg/L
worst single sample: 7.2 µg/L
4/31 SYR4 2013–2017
Nitrate
300 µg/L 3%
of the EPA limit 10000 µg/L
4/16 SYR4 2012–2019
Di(2-ethylhexyl) Phthalate
3.065 µg/L 51%
of the EPA limit 6 µg/L
worst single sample: 3.1 µg/L
2/6 SYR4 2017–2019
Nitrate-Nitrite
299 µg/L 3%
of the EPA limit 10000 µg/L
worst single sample: 300 µg/L
2/8 SYR4 2012–2019
Lithium
120 µg/L
No EPA limit set
2/2 UCMR-5 2023
Barium
30 µg/L 1.5%
of the EPA limit 2000 µg/L
1/1 SYR4 2014
Bromodichloromethane
5.9 µg/L
No EPA limit set
1/1 SYR4 2019
Bromoform
1.9 µg/L
No EPA limit set
1/1 SYR4 2019
Chloroform
3.9 µg/L
No EPA limit set
1/1 SYR4 2019
Dibromochloromethane
7 µg/L
No EPA limit set
1/1 SYR4 2019
Fluoride
380 µg/L 9.5%
of the EPA limit 4000 µg/L
1/1 SYR4 2014
Gross Alpha, Excl. Radon And U
3.5 pCi/L 23%
of the EPA limit 15 pCi/L
1/1 SYR4 2016
Selenium
3.7 µg/L 7.4%
of the EPA limit 50 µg/L
1/1 SYR4 2014
88 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,3,7,8-TCDD2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined Radium (-226 And -228)DichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
RYMER, ADAM
Phone
828-507-8457
Email
[email protected]

Frequently asked questions about Glen Canyon Nra Wahweap

Is Glen Canyon Nra Wahweap tap water safe to drink?

EPA monitoring detected 18 contaminants in Glen Canyon Nra Wahweap's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Glen Canyon Nra Wahweap's water?

EPA monitoring detected Copper, TTHM, Total Haloacetic Acids (HAA5), Lead, Lead, and others. The full list with the level and data source for each is above.

How many people does Glen Canyon Nra Wahweap serve?

Glen Canyon Nra Wahweap reports serving 579 people in Arizona, per its EPA record.

Has Glen Canyon Nra Wahweap had any water quality violations?

The EPA has 385 violations on file for Glen Canyon Nra Wahweap, of which 5 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.