← Arkansas

Tap water quality report

South Pike Co Water

EPA monitoring tested this supplier for 14 contaminants and detected 11. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

14
contaminants tested
11
detected
755
people served
59
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Pike

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

59
health-based violations
76
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2020-01-01 → 2020-03-31
MCL Health-based Resolved 2020-01-01 → 2020-03-31
MCL Health-based Resolved 2020-01-01 → 2020-03-31
MCL Health-based Resolved 2019-10-01 → 2019-12-31
MCL Health-based Resolved 2019-10-01 → 2019-12-31
MCL Health-based Resolved 2019-10-01 → 2019-12-31
MCL Health-based Resolved 2019-10-01 → 2019-12-31
MCL Health-based Resolved 2019-04-01 → 2019-06-30
MCL Health-based Resolved 2019-04-01 → 2019-06-30
MCL Health-based Resolved 2019-04-01 → 2019-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
9.585 µg/L
No EPA limit set
worst single sample: 9.9 µg/L
64/64 SYR4 2012–2019
Chloroform
96.96 µg/L
No EPA limit set
worst single sample: 109 µg/L
64/64 SYR4 2012–2019
TTHM
102.395 µg/L 128%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 118 µg/L
64/64 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
31.235 µg/L 52%
of the EPA limit 60 µg/L
worst single sample: 66.1 µg/L
44/64 SYR4 2012–2019
Dichloroacetic Acid
5.03 µg/L
No EPA limit set
worst single sample: 31.3 µg/L
43/64 SYR4 2012–2019
Trichloroacetic Acid
31.18 µg/L
No EPA limit set
worst single sample: 34 µg/L
29/64 SYR4 2012–2019
Dibromochloromethane
1.6 µg/L
No EPA limit set
20/64 SYR4 2012–2019
Copper
1112 µg/L 86%
of the EPA limit 1300 µg/L
worst single sample: 1220 µg/L
9/20 SYR4 2012–2019
Lead
3.28 µg/L 22%
of the EPA limit 15 µg/L
worst single sample: 3.5 µg/L
3/20 SYR4 2012–2019
Lead
0.0340 mg/L 227%
above the EPA limit of 0.0150 mg/L
1/1 LCR 2009
Monochloroacetic Acid
2.7 µg/L
No EPA limit set
1/64 SYR4 2012–2019
3 contaminants tested, none detected
BromoformDibromoacetic AcidMonobromoacetic Acid

Utility contact

Contact
CHISM, LANE
Phone
870-285-2257

Frequently asked questions about South Pike Co Water

Is South Pike Co Water tap water safe to drink?

EPA monitoring detected 11 contaminants in South Pike Co Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in South Pike Co Water's water?

EPA monitoring detected Bromodichloromethane, Chloroform, TTHM, Total Haloacetic Acids (HAA5), Dichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does South Pike Co Water serve?

South Pike Co Water reports serving 755 people in Arkansas, per its EPA record.

Has South Pike Co Water had any water quality violations?

The EPA has 76 violations on file for South Pike Co Water, of which 59 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.