Tap water quality report

Greenhill Water & Fire Pro Authority

EPA monitoring tested this supplier for 104 contaminants and detected 20. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

104
contaminants tested
20
detected
8,214
people served
4
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Lauderdale

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
21
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2010-11-01 → 2010-11-30
MCL Health-based Resolved 2010-11-01 → 2010-11-30
MCL Health-based Resolved 2010-11-01 → 2010-11-30
MCL Health-based Resolved 2010-11-01 → 2010-11-30
MR Monitoring Resolved 2017-01-01 → 2019-12-31
MR Monitoring Resolved 2017-01-01 → 2019-12-31
MR Monitoring Resolved 2017-01-01 → 2019-12-31
MR Monitoring Resolved 2017-01-01 → 2019-12-31
MR Monitoring Resolved 2017-01-01 → 2019-12-31
MR Monitoring Resolved 2017-01-01 → 2019-12-31

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
PFOA 0.0106 µg/L 4/6 2025
PFOS 0.0223 µg/L 4/6 2025
Pfba 0.0133 µg/L 3/6 2025
PFBS 0.0043 µg/L 3/6 2025
Pfhxa 0.0042 µg/L 3/6 2025
Pfhpa 0.0031 µg/L 2/6 2025

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
53.56 µg/L 67%
of the EPA limit 80 µg/L
worst single sample: 59.6 µg/L
63/64 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
34.7 µg/L 58%
of the EPA limit 60 µg/L
worst single sample: 61.6 µg/L
63/64 SYR4 2012–2019
Lead
0.0014 mg/L 9.4%
of the EPA limit 0.0150 mg/L
26/26 LCR 2024
Copper
96.535 µg/L 7.4%
of the EPA limit 1300 µg/L
worst single sample: 121 µg/L
24/24 SYR4 2013–2019
Nitrate
2734 µg/L 27%
of the EPA limit 10000 µg/L
worst single sample: 2740 µg/L
24/24 SYR4 2012–2019
Nitrate-Nitrite
2718 µg/L 27%
of the EPA limit 10000 µg/L
worst single sample: 2740 µg/L
12/12 SYR4 2012–2019
Di(2-ethylhexyl) Phthalate
0.4180 µg/L 7%
of the EPA limit 6 µg/L
worst single sample: 0.4600 µg/L
3/6 SYR4 2013–2019
Fluoride
22.7 µg/L 0.6%
of the EPA limit 4000 µg/L
worst single sample: 23 µg/L
3/3 SYR4 2013–2019
Lead
7.367 µg/L 49%
of the EPA limit 15 µg/L
worst single sample: 7.86 µg/L
3/24 SYR4 2013–2019
Barium
13.5912 µg/L 0.7%
of the EPA limit 2000 µg/L
worst single sample: 13.6 µg/L
2/3 SYR4 2013–2019
Chromium
0.6796 µg/L 0.7%
of the EPA limit 100 µg/L
worst single sample: 0.6820 µg/L
2/3 SYR4 2013–2019
Chloroform
0.0430 µg/L
No EPA limit set
1/4 SYR4 2013–2019
Gross Alpha, Excl. Radon And U
1.17 pCi/L 7.8%
of the EPA limit 15 pCi/L
1/2 SYR4 2014
Nitrite
2 µg/L 0.2%
of the EPA limit 1000 µg/L
1/12 SYR4 2012–2019
84 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDibromochloromethaneDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaOxamylPfdaPfdoaPfeesaPfhpsPFHXSPfmbaPfmpaPFNAPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
WALLACE, THOMAS J.
Email
[email protected]

Frequently asked questions about Greenhill Water & Fire Pro Authority

Is Greenhill Water & Fire Pro Authority tap water safe to drink?

EPA monitoring detected 20 contaminants in Greenhill Water & Fire Pro Authority's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Greenhill Water & Fire Pro Authority's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Lead, Copper, Nitrate, and others. The full list with the level and data source for each is above.

How many people does Greenhill Water & Fire Pro Authority serve?

Greenhill Water & Fire Pro Authority reports serving 8,214 people in Alabama, per its EPA record.

Has Greenhill Water & Fire Pro Authority had any water quality violations?

The EPA has 21 violations on file for Greenhill Water & Fire Pro Authority, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.