← Alabama

Tap water quality report

Citizens Water Service, Inc.

EPA monitoring tested this supplier for 104 contaminants and detected 8. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

104
contaminants tested
8
detected
15,096
people served
9
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Tuscaloosa

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

9
health-based violations
19
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 1994-10-01 → 1994-10-31
MCL Health-based Archived 1994-10-01 → 1994-10-31
MCL Health-based Archived 1994-10-01 → 1994-10-31
MCL Health-based Archived 1993-01-01 → 1993-01-31
MCL Health-based Archived 1993-01-01 → 1993-01-31
MCL Health-based Archived 1993-01-01 → 1993-01-31
MCL Health-based Archived 1993-01-01 → 1993-01-31
MCL Health-based Archived 1991-06-01 → 1991-06-30
MCL Health-based Archived 1991-06-01 → 1991-06-30
MON Monitoring Resolved 2024-11-01 → 2024-11-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
53.56 µg/L 67%
of the EPA limit 80 µg/L
worst single sample: 60.6 µg/L
128/128 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
45.09 µg/L 75%
of the EPA limit 60 µg/L
worst single sample: 64 µg/L
128/128 SYR4 2012–2019
Copper
122 µg/L 9.4%
of the EPA limit 1300 µg/L
worst single sample: 242 µg/L
57/62 SYR4 2012–2019
Nitrate
609 µg/L 6.1%
of the EPA limit 10000 µg/L
worst single sample: 620 µg/L
32/32 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
20/20 LCR 2025
Nitrate-Nitrite
570 µg/L 5.7%
of the EPA limit 10000 µg/L
6/6 SYR4 2012–2019
Lead
62.295 µg/L 415%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 72 µg/L
4/65 SYR4 2012–2019
Gross Alpha, Excl. Radon And U
0.5000 pCi/L 3.3%
of the EPA limit 15 pCi/L
1/1 SYR4 2019
96 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromochloromethaneDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneFluorideGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
HERRING, KENNY
Phone
205-556-2224
Email
[email protected]

Frequently asked questions about Citizens Water Service, Inc.

Is Citizens Water Service, Inc. tap water safe to drink?

EPA monitoring detected 8 contaminants in Citizens Water Service, Inc.'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Citizens Water Service, Inc.'s water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Copper, Nitrate, Lead, and others. The full list with the level and data source for each is above.

How many people does Citizens Water Service, Inc. serve?

Citizens Water Service, Inc. reports serving 15,096 people in Alabama, per its EPA record.

Has Citizens Water Service, Inc. had any water quality violations?

The EPA has 19 violations on file for Citizens Water Service, Inc., of which 9 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.