← Alabama

Tap water quality report

West Lauderdale Co, Water & Fpa

EPA monitoring tested this supplier for 33 contaminants and detected 9. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

33
contaminants tested
9
detected
15,681
people served
6
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Lauderdale

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

6
health-based violations
16
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2014-09-01 → 2014-09-30
MCL Health-based Resolved 2014-09-01 → 2014-09-30
MCL Health-based Resolved 2014-09-01 → 2014-09-30
MCL Health-based Resolved 2014-09-01 → 2014-09-30
MCL Health-based Archived 1999-01-01 → 1999-01-31
MCL Health-based Archived 1999-01-01 → 1999-01-31
MR Monitoring Resolved 2014-12-01 → 2014-12-31
MR Monitoring Resolved 2014-12-01 → 2014-12-31
MR Monitoring Resolved 2014-12-01 → 2014-12-31
MR Monitoring Resolved 2012-03-01 → 2012-03-31

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Pfba 0.0077 µg/L 2/4 2025
PFBS 0.0044 µg/L 2/4 2025
Pfhxa 0.0039 µg/L 2/4 2025
PFOA 0.0130 µg/L 2/4 2025
PFOS 0.0170 µg/L 2/4 2025
Pfhpa 0.0031 µg/L 1/4 2025

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Total Haloacetic Acids (HAA5)
70.09 µg/L 117%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 126 µg/L
139/139 SYR4 2012–2019
TTHM
74.145 µg/L 93%
of the EPA limit 80 µg/L
worst single sample: 96.4 µg/L
138/138 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
18/18 LCR 2023
24 contaminants tested, none detected
11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaHfpo-DaNetfosaaNfdhaNmefosaaPfdaPfdoaPfeesaPfhpsPFHXSPfmbaPfmpaPFNAPfpeaPfpesPftaPftrdaPfunaLithium

Utility contact

Contact
MILES, DEBORAH
Phone
256-766-8787
Email
[email protected]

Frequently asked questions about West Lauderdale Co, Water & Fpa

Is West Lauderdale Co, Water & Fpa tap water safe to drink?

EPA monitoring detected 9 contaminants in West Lauderdale Co, Water & Fpa's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in West Lauderdale Co, Water & Fpa's water?

EPA monitoring detected Total Haloacetic Acids (HAA5), TTHM, Lead, Pfba, PFBS, and others. The full list with the level and data source for each is above.

How many people does West Lauderdale Co, Water & Fpa serve?

West Lauderdale Co, Water & Fpa reports serving 15,681 people in Alabama, per its EPA record.

Has West Lauderdale Co, Water & Fpa had any water quality violations?

The EPA has 16 violations on file for West Lauderdale Co, Water & Fpa, of which 6 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.