| Violation | Type | Status | Period |
|---|---|---|---|
| MR | Monitoring | Archived | 2024-10-01 → 2024-12-31 |
| MR | Monitoring | Archived | 2024-10-01 → 2024-12-31 |
| MR | Monitoring | Archived | 2024-10-01 → 2024-12-31 |
| MR | Monitoring | Archived | 2024-10-01 → 2024-12-31 |
| MR | Monitoring | Archived | 2024-10-01 → 2024-12-31 |
| MR | Monitoring | Archived | 2024-10-01 → 2024-12-31 |
| MON | Monitoring | Resolved | 2021-07-01 → 2021-07-31 |
| MON | Monitoring | Resolved | 2021-07-01 → 2021-07-31 |
| MON | Monitoring | Resolved | 2021-07-01 → 2021-07-31 |
| MON | Monitoring | Resolved | 2021-07-01 → 2021-07-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 200 µg/L 2% of the EPA limit 10000 µg/L
worst single sample: 210 µg/L | 44/98 | SYR4 | 2012–2019 |
| Copper | 189.15 µg/L 15% of the EPA limit 1300 µg/L
worst single sample: 464 µg/L | 24/39 | SYR4 | 2013–2019 |
| Chloroform | 2.8025 µg/L No EPA limit set
worst single sample: 2.85 µg/L | 20/34 | SYR4 | 2012–2019 |
| Lead | 0.0023 mg/L 15% of the EPA limit 0.0150 mg/L | 20/20 | LCR | 2025 |
| Bromodichloromethane | 6.32 µg/L No EPA limit set
worst single sample: 6.8 µg/L | 17/34 | SYR4 | 2012–2019 |
| Dibromochloromethane | 17.85 µg/L No EPA limit set
worst single sample: 18 µg/L | 16/34 | SYR4 | 2012–2019 |
| Bromoform | 22.51 µg/L No EPA limit set
worst single sample: 23.7 µg/L | 15/34 | SYR4 | 2012–2019 |
| TTHM | 74.81 µg/L 94% of the EPA limit 80 µg/L
worst single sample: 97.7 µg/L | 15/16 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 13.24 µg/L 22% of the EPA limit 60 µg/L
worst single sample: 13.8 µg/L | 15/16 | SYR4 | 2012–2019 |
| Fluoride | 620 µg/L 16% of the EPA limit 4000 µg/L
worst single sample: 640 µg/L | 9/19 | SYR4 | 2013–2019 |
| Lead | 10.85 µg/L 72% of the EPA limit 15 µg/L
worst single sample: 14 µg/L | 8/39 | SYR4 | 2013–2019 |
| Nitrate-Nitrite | 206.5 µg/L 2.1% of the EPA limit 10000 µg/L
worst single sample: 210 µg/L | 8/19 | SYR4 | 2013–2019 |
| Gross Alpha, Excl. Radon And U | 3.344 pCi/L 22% of the EPA limit 15 pCi/L
worst single sample: 3.5 pCi/L | 7/8 | SYR4 | 2012–2019 |
| Lithium | 16.7 µg/L No EPA limit set | 4/7 | UCMR-5 | 2025 |
| Barium | 25.55 µg/L 1.3% of the EPA limit 2000 µg/L
worst single sample: 26 µg/L | 2/19 | SYR4 | 2013–2019 |
| Xylenes, Total | 0.7565 µg/L 0% of the EPA limit 10000 µg/L
worst single sample: 0.7600 µg/L | 2/34 | SYR4 | 2012–2019 |
| Carbon Tetrachloride | 0.7700 µg/L 15% of the EPA limit 5 µg/L | 1/34 | SYR4 | 2012–2019 |
87 contaminants tested, none detected
Utility contact
Frequently asked questions about Geneva, the Ww & Sb of the City of
Is Geneva, the Ww & Sb of the City of tap water safe to drink?
EPA monitoring detected 17 contaminants in Geneva, the Ww & Sb of the City of's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Geneva, the Ww & Sb of the City of's water?
EPA monitoring detected Nitrate, Copper, Chloroform, Lead, Bromodichloromethane, and others. The full list with the level and data source for each is above.
How many people does Geneva, the Ww & Sb of the City of serve?
Geneva, the Ww & Sb of the City of reports serving 9,600 people in Alabama, per its EPA record.
Has Geneva, the Ww & Sb of the City of had any water quality violations?
The EPA has 24 violations on file for Geneva, the Ww & Sb of the City of, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.