Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MR | Monitoring | Resolved | 2016-03-15 → 2016-06-13 |
| MR | Monitoring | Resolved | 2016-03-15 → 2016-06-13 |
| MR | Monitoring | Resolved | 2016-03-15 → 2016-06-13 |
| MR | Monitoring | Resolved | 2016-03-15 → 2016-06-13 |
| MR | Monitoring | Resolved | 2016-03-15 → 2016-06-13 |
| MR | Monitoring | Resolved | 2016-03-15 → 2016-06-13 |
| MR | Monitoring | Resolved | 2016-03-15 → 2016-06-13 |
| MR | Monitoring | Resolved | 2016-03-15 → 2016-06-13 |
| MR | Monitoring | Resolved | 2015-12-15 → 2016-03-14 |
| MR | Monitoring | Resolved | 2015-12-15 → 2016-03-14 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Total Haloacetic Acids (HAA5) | 57.04 µg/L 95% of the EPA limit 60 µg/L
worst single sample: 78 µg/L | 193/193 | SYR4 | 2012–2019 |
| TTHM | 85.09 µg/L 106% of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 99.9 µg/L | 192/192 | SYR4 | 2012–2019 |
| Copper | 140.95 µg/L 11% of the EPA limit 1300 µg/L
worst single sample: 230 µg/L | 38/39 | SYR4 | 2012–2019 |
| Chlorite | 708 µg/L 71% of the EPA limit 1000 µg/L
worst single sample: 760 µg/L | 32/33 | SYR4 | 2019 |
| Lead | 0.00041 mg/L 2.7% of the EPA limit 0.0150 mg/L | 19/19 | LCR | 2025 |
| Nitrate | 146 µg/L 1.5% of the EPA limit 10000 µg/L | 14/18 | SYR4 | 2012–2019 |
| Fluoride | 910 µg/L 23% of the EPA limit 4000 µg/L
worst single sample: 930 µg/L | 9/9 | SYR4 | 2012–2019 |
| Lead | 0.8520 µg/L 5.7% of the EPA limit 15 µg/L
worst single sample: 1.1 µg/L | 9/39 | SYR4 | 2012–2019 |
| Barium | 13.055 µg/L 0.7% of the EPA limit 2000 µg/L
worst single sample: 13.3 µg/L | 8/9 | SYR4 | 2012–2019 |
| Nitrate-Nitrite | 148.5 µg/L 1.5% of the EPA limit 10000 µg/L
worst single sample: 173 µg/L | 8/8 | SYR4 | 2012–2019 |
| Chloroform | 78.35 µg/L No EPA limit set
worst single sample: 99.8 µg/L | 7/8 | SYR4 | 2012–2019 |
| Arsenic | 1 µg/L 10% of the EPA limit 10 µg/L | 6/9 | SYR4 | 2012–2019 |
| Bromodichloromethane | 4.0525 µg/L No EPA limit set
worst single sample: 4.41 µg/L | 6/8 | SYR4 | 2012–2019 |
| Dibromochloromethane | 0.7720 µg/L No EPA limit set
worst single sample: 0.8600 µg/L | 5/8 | SYR4 | 2012–2019 |
| Antimony, Total | 0.9240 µg/L 15% of the EPA limit 6 µg/L
worst single sample: 0.9400 µg/L | 3/9 | SYR4 | 2012–2019 |
| Nitrite | 25.95 µg/L 2.6% of the EPA limit 1000 µg/L
worst single sample: 27 µg/L | 2/9 | SYR4 | 2012–2019 |
| Thallium, Total | 1.1 µg/L 55% of the EPA limit 2 µg/L | 1/9 | SYR4 | 2012–2019 |
87 contaminants tested, none detected
Utility contact
Frequently asked questions about Central Elmore Water & Sewer Authority
Is Central Elmore Water & Sewer Authority tap water safe to drink?
EPA monitoring detected 17 contaminants in Central Elmore Water & Sewer Authority's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Central Elmore Water & Sewer Authority's water?
EPA monitoring detected Total Haloacetic Acids (HAA5), TTHM, Copper, Chlorite, Lead, and others. The full list with the level and data source for each is above.
How many people does Central Elmore Water & Sewer Authority serve?
Central Elmore Water & Sewer Authority reports serving 39,798 people in Alabama, per its EPA record.
Has Central Elmore Water & Sewer Authority had any water quality violations?
The EPA has 43 violations on file for Central Elmore Water & Sewer Authority, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.