← Alabama

Tap water quality report

Collinsville Water Works

EPA monitoring tested this supplier for 35 contaminants and detected 10. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

35
contaminants tested
10
detected
3,945
people served
0
health-based violations
Water source
SWP
Ownership
Local government
Counties served
DeKalb

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
14
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2017-10-11
MR Monitoring Resolved 2017-10-11
MR Monitoring Resolved 2017-10-11
MR Monitoring Resolved 2017-10-11
MR Monitoring Archived 2003-09-01 → 2003-09-30
MR Monitoring Archived 2003-09-01 → 2003-09-30
MR Monitoring Archived 1997-08-01 → 1997-08-31
MR Monitoring Archived 1997-08-01 → 1997-08-31
MR Monitoring Archived 1997-08-01 → 1997-08-31
MR Monitoring Archived 1994-12-01 → 1994-12-31

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Pfhxa 0.0068 µg/L 4/8 2025
Pfhpa 0.0069 µg/L 2/8 2025
PFOA 0.0525 µg/L 2/8 2025
PFOS 0.0066 µg/L 2/8 2025
Pfpea 0.0047 µg/L 2/8 2025

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
74.445 µg/L 93%
of the EPA limit 80 µg/L
worst single sample: 92.4 µg/L
122/122 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
53.27 µg/L 89%
of the EPA limit 60 µg/L
worst single sample: 67.3 µg/L
122/122 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
19/19 LCR 2023
Copper
413.4 µg/L 32%
of the EPA limit 1300 µg/L
worst single sample: 417 µg/L
10/20 SYR4 2018
Lead
6 µg/L 40%
of the EPA limit 15 µg/L
1/20 SYR4 2018
25 contaminants tested, none detected
11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaHfpo-DaNetfosaaNfdhaNmefosaaPfbaPFBSPfdaPfdoaPfeesaPfhpsPFHXSPfmbaPfmpaPFNAPfpesPftaPftrdaPfunaLithium

Utility contact

Contact
BOX III, MUNSEY
Phone
256-524-2188
Email
[email protected]

Frequently asked questions about Collinsville Water Works

Is Collinsville Water Works tap water safe to drink?

EPA monitoring detected 10 contaminants in Collinsville Water Works's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Collinsville Water Works's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Lead, Copper, Pfhxa, and others. The full list with the level and data source for each is above.

How many people does Collinsville Water Works serve?

Collinsville Water Works reports serving 3,945 people in Alabama, per its EPA record.

Has Collinsville Water Works had any water quality violations?

The EPA has 14 violations on file for Collinsville Water Works, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.