Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Archived | 1996-03-01 → 1996-03-31 |
| MCL | Health-based | Archived | 1996-03-01 → 1996-03-31 |
| MCL | Health-based | Archived | 1996-03-01 → 1996-03-31 |
| RPT | Monitoring | Resolved | 2022-04-11 |
| RPT | Monitoring | Resolved | 2022-04-11 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 216.5 µg/L 2.2% of the EPA limit 10000 µg/L
worst single sample: 220 µg/L | 28/64 | SYR4 | 2012–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 18/18 | LCR | 2023 |
| TTHM | 5.547 µg/L 6.9% of the EPA limit 80 µg/L
worst single sample: 6.34 µg/L | 14/16 | SYR4 | 2012–2019 |
| Chloroform | 3.39 µg/L No EPA limit set
worst single sample: 4.17 µg/L | 6/12 | SYR4 | 2012–2017 |
| Bromodichloromethane | 1.584 µg/L No EPA limit set
worst single sample: 1.82 µg/L | 5/12 | SYR4 | 2012–2017 |
| Nitrate-Nitrite | 200 µg/L 2% of the EPA limit 10000 µg/L | 5/12 | SYR4 | 2013–2019 |
| Gross Alpha, Excl. Radon And U | 0.4700 pCi/L 3.1% of the EPA limit 15 pCi/L
worst single sample: 0.5000 pCi/L | 4/4 | SYR4 | 2019 |
| Total Haloacetic Acids (HAA5) | 6.4405 µg/L 11% of the EPA limit 60 µg/L
worst single sample: 7 µg/L | 4/16 | SYR4 | 2012–2019 |
| Dibromochloromethane | 1.167 µg/L No EPA limit set
worst single sample: 1.2 µg/L | 2/12 | SYR4 | 2012–2017 |
95 contaminants tested, none detected
Utility contact
Frequently asked questions about Level Plains, Town of
Is Level Plains, Town of tap water safe to drink?
EPA monitoring detected 9 contaminants in Level Plains, Town of's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Level Plains, Town of's water?
EPA monitoring detected Nitrate, Lead, TTHM, Chloroform, Bromodichloromethane, and others. The full list with the level and data source for each is above.
How many people does Level Plains, Town of serve?
Level Plains, Town of reports serving 3,819 people in Alabama, per its EPA record.
Has Level Plains, Town of had any water quality violations?
The EPA has 5 violations on file for Level Plains, Town of, of which 3 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?