Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Archived | 2003-06-01 → 2003-06-30 |
| MCL | Health-based | Archived | 2003-06-01 → 2003-06-30 |
| MCL | Health-based | Archived | 1996-07-01 → 1996-07-31 |
| MCL | Health-based | Archived | 1996-07-01 → 1996-07-31 |
| MCL | Health-based | Archived | 1996-07-01 → 1996-07-31 |
| Other | Monitoring | Unaddressed | 2024-01-01 |
| Other | Monitoring | Resolved | 2023-10-01 |
| Other | Monitoring | Resolved | 2023-10-01 |
| Other | Monitoring | Resolved | 2023-10-01 |
| Other | Monitoring | Resolved | 2023-10-01 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Lead | 0.0013 mg/L 8.7% of the EPA limit 0.0150 mg/L | 33/33 | LCR | 2025 |
| Copper | 130 µg/L 10% of the EPA limit 1300 µg/L
worst single sample: 140 µg/L | 23/32 | SYR4 | 2013–2019 |
| Total Haloacetic Acids (HAA5) | 4.931 µg/L 8.2% of the EPA limit 60 µg/L
worst single sample: 7.85 µg/L | 15/16 | SYR4 | 2012–2019 |
| Fluoride | 3852 µg/L 96% of the EPA limit 4000 µg/L
worst single sample: 4230 µg/L | 13/13 | SYR4 | 2013–2019 |
| TTHM | 13.78 µg/L 17% of the EPA limit 80 µg/L
worst single sample: 16 µg/L | 13/16 | SYR4 | 2012–2019 |
| Nitrate | 210 µg/L 2.1% of the EPA limit 10000 µg/L | 12/64 | SYR4 | 2012–2019 |
| Lead | 3.975 µg/L 27% of the EPA limit 15 µg/L
worst single sample: 4.7 µg/L | 6/32 | SYR4 | 2013–2019 |
| Dibromochloromethane | 0.9840 µg/L No EPA limit set
worst single sample: 1.01 µg/L | 3/13 | SYR4 | 2012–2019 |
| Gross Alpha, Excl. Radon And U | 2.69 pCi/L 18% of the EPA limit 15 pCi/L
worst single sample: 2.9 pCi/L | 3/3 | SYR4 | 2019 |
| Nitrate-Nitrite | 199 µg/L 2% of the EPA limit 10000 µg/L
worst single sample: 200 µg/L | 3/13 | SYR4 | 2013–2019 |
| Barium | 13.85 µg/L 0.7% of the EPA limit 2000 µg/L
worst single sample: 14 µg/L | 2/12 | SYR4 | 2013–2019 |
| Bromoform | 1.184 µg/L No EPA limit set
worst single sample: 1.2 µg/L | 2/13 | SYR4 | 2012–2019 |
| Lithium | 12.3 µg/L No EPA limit set | 2/8 | UCMR-5 | 2024 |
| Arsenic | 1.1 µg/L 11% of the EPA limit 10 µg/L | 1/12 | SYR4 | 2013–2019 |
| Bromodichloromethane | 0.5300 µg/L No EPA limit set | 1/13 | SYR4 | 2012–2019 |
89 contaminants tested, none detected
Utility contact
Frequently asked questions about Daleville, the Wwsb of the City of
Is Daleville, the Wwsb of the City of tap water safe to drink?
EPA monitoring detected 15 contaminants in Daleville, the Wwsb of the City of's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Daleville, the Wwsb of the City of's water?
EPA monitoring detected Lead, Copper, Total Haloacetic Acids (HAA5), Fluoride, TTHM, and others. The full list with the level and data source for each is above.
How many people does Daleville, the Wwsb of the City of serve?
Daleville, the Wwsb of the City of reports serving 10,014 people in Alabama, per its EPA record.
Has Daleville, the Wwsb of the City of had any water quality violations?
The EPA has 113 violations on file for Daleville, the Wwsb of the City of, of which 5 are health-based (a contaminant limit or required treatment was breached) and 3 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.