Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Resolved | 2022-10-29 |
| TT | Health-based | Resolved | 2022-10-29 |
| TT | Health-based | Resolved | 2022-10-29 |
| TT | Health-based | Resolved | 2022-10-29 |
| MR | Monitoring | Archived | 2023-01-01 → 2025-12-31 |
| MR | Monitoring | Resolved | 2022-09-10 |
| MR | Monitoring | Resolved | 2022-09-10 |
| MR | Monitoring | Resolved | 2022-09-10 |
| MR | Monitoring | Resolved | 2022-09-10 |
| MR | Monitoring | Resolved | 2022-09-10 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 1064.5 µg/L 11% of the EPA limit 10000 µg/L
worst single sample: 1070 µg/L | 22/54 | SYR4 | 2012–2019 |
| Lead | 0.0110 mg/L 73% of the EPA limit 0.0150 mg/L | 18/18 | LCR | 2024 |
| Copper | 136.5 µg/L 11% of the EPA limit 1300 µg/L
worst single sample: 238 µg/L | 15/22 | SYR4 | 2013–2019 |
| TTHM | 17.08 µg/L 21% of the EPA limit 80 µg/L
worst single sample: 18.1 µg/L | 13/16 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 8.46 µg/L 14% of the EPA limit 60 µg/L
worst single sample: 10.1 µg/L | 9/16 | SYR4 | 2012–2019 |
| Chloroform | 2.123 µg/L No EPA limit set
worst single sample: 2.25 µg/L | 3/10 | SYR4 | 2012–2017 |
| Gross Alpha, Excl. Radon And U | 2.6949 pCi/L 18% of the EPA limit 15 pCi/L
worst single sample: 2.92 pCi/L | 3/3 | SYR4 | 2019 |
| Nitrate-Nitrite | 949 µg/L 9.5% of the EPA limit 10000 µg/L
worst single sample: 960 µg/L | 3/13 | SYR4 | 2013–2019 |
66 contaminants tested, none detected
Utility contact
Frequently asked questions about Coffeeville Utiliies Board
Is Coffeeville Utiliies Board tap water safe to drink?
EPA monitoring detected 8 contaminants in Coffeeville Utiliies Board's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Coffeeville Utiliies Board's water?
EPA monitoring detected Nitrate, Lead, Copper, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.
How many people does Coffeeville Utiliies Board serve?
Coffeeville Utiliies Board reports serving 2,730 people in Alabama, per its EPA record.
Has Coffeeville Utiliies Board had any water quality violations?
The EPA has 27 violations on file for Coffeeville Utiliies Board, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.