| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2020-10-01 → 2020-12-31 |
| MCL | Health-based | Resolved | 2020-10-01 → 2020-12-31 |
| MCL | Health-based | Resolved | 2020-10-01 → 2020-12-31 |
| MCL | Health-based | Resolved | 2020-10-01 → 2020-12-31 |
| MCL | Health-based | Resolved | 1997-04-01 → 1997-06-30 |
| MCL | Health-based | Resolved | 1997-04-01 → 1997-06-30 |
| MCL | Health-based | Resolved | 1997-04-01 → 1997-06-30 |
| MR | Monitoring | Resolved | 2022-01-01 → 2022-12-31 |
| MR | Monitoring | Resolved | 2022-01-01 → 2022-12-31 |
| MR | Monitoring | Resolved | 2022-01-01 → 2022-12-31 |
PFAS detected
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Total Haloacetic Acids (HAA5) | 59.435 µg/L 99% of the EPA limit 60 µg/L
worst single sample: 104 µg/L | 152/152 | SYR4 | 2012–2019 |
| TTHM | 74.75 µg/L 93% of the EPA limit 80 µg/L
worst single sample: 82.4 µg/L | 151/152 | SYR4 | 2012–2019 |
| Chlorite | 645.55 µg/L 65% of the EPA limit 1000 µg/L
worst single sample: 888 µg/L | 110/111 | SYR4 | 2013–2019 |
| Copper | 159 µg/L 12% of the EPA limit 1300 µg/L
worst single sample: 180 µg/L | 23/29 | SYR4 | 2012–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 20/20 | LCR | 2024 |
| Nitrate | 480 µg/L 4.8% of the EPA limit 10000 µg/L | 18/18 | SYR4 | 2012–2019 |
| Nitrate-Nitrite | 480 µg/L 4.8% of the EPA limit 10000 µg/L | 9/9 | SYR4 | 2012–2019 |
| Fluoride | 866.5 µg/L 22% of the EPA limit 4000 µg/L
worst single sample: 940 µg/L | 8/9 | SYR4 | 2012–2019 |
| Barium | 95.5 µg/L 4.8% of the EPA limit 2000 µg/L
worst single sample: 100 µg/L | 4/9 | SYR4 | 2012–2019 |
| Bromodichloromethane | 11.998 µg/L No EPA limit set
worst single sample: 12.7 µg/L | 3/3 | SYR4 | 2012–2018 |
| Chloroform | 29.589 µg/L No EPA limit set
worst single sample: 32 µg/L | 3/3 | SYR4 | 2012–2018 |
| Dibromochloromethane | 4.042 µg/L No EPA limit set
worst single sample: 4.2 µg/L | 3/3 | SYR4 | 2012–2018 |
| Chromium | 7.9 µg/L 7.9% of the EPA limit 100 µg/L
worst single sample: 8 µg/L | 2/9 | SYR4 | 2012–2019 |
| Gross Alpha, Excl. Radon And U | 1.7 pCi/L 11% of the EPA limit 15 pCi/L | 2/2 | SYR4 | 2012–2018 |
| Cadmium | 1 µg/L 20% of the EPA limit 5 µg/L | 1/9 | SYR4 | 2012–2019 |
| Selenium | 3 µg/L 6% of the EPA limit 50 µg/L | 1/9 | SYR4 | 2012–2019 |
83 contaminants tested, none detected
Utility contact
Frequently asked questions about Centre Water & Sewer Board
Is Centre Water & Sewer Board tap water safe to drink?
EPA monitoring detected 22 contaminants in Centre Water & Sewer Board's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Centre Water & Sewer Board's water?
EPA monitoring detected Total Haloacetic Acids (HAA5), TTHM, Chlorite, Copper, Lead, and others. The full list with the level and data source for each is above.
How many people does Centre Water & Sewer Board serve?
Centre Water & Sewer Board reports serving 7,050 people in Alabama, per its EPA record.