← Alabama

Tap water quality report

Blountsville, the Ub of the Town of

EPA monitoring tested this supplier for 104 contaminants and detected 9. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

104
contaminants tested
9
detected
4,266
people served
4
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Blount

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
14
violations on file
3
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2012-05-01 → 2012-05-31
MCL Health-based Resolved 2012-05-01 → 2012-05-31
MCL Health-based Resolved 2012-05-01 → 2012-05-31
MCL Health-based Resolved 2012-05-01 → 2012-05-31
MR Monitoring Unaddressed 2021-01-01
MR Monitoring Unaddressed 2021-01-01
MR Monitoring Unaddressed 2021-01-01
MR Monitoring Resolved 2014-10-04
MR Monitoring Resolved 2012-01-01
MR Monitoring Resolved 2012-01-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
1798 µg/L 18%
of the EPA limit 10000 µg/L
worst single sample: 1820 µg/L
32/32 SYR4 2012–2019
Lead
0.0016 mg/L 11%
of the EPA limit 0.0150 mg/L
16/16 LCR 2023
Nitrate-Nitrite
1700 µg/L 17%
of the EPA limit 10000 µg/L
worst single sample: 1730 µg/L
6/6 SYR4 2013–2019
TTHM
3.752 µg/L 4.7%
of the EPA limit 80 µg/L
worst single sample: 4.09 µg/L
5/16 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
13.92 µg/L 23%
of the EPA limit 60 µg/L
worst single sample: 14.1 µg/L
5/16 SYR4 2012–2019
Bromodichloromethane
0.6335 µg/L
No EPA limit set
worst single sample: 0.6400 µg/L
2/6 SYR4 2012–2017
Chloroform
0.8505 µg/L
No EPA limit set
worst single sample: 0.8600 µg/L
2/6 SYR4 2012–2017
Gross Alpha, Excl. Radon And U
0.7850 pCi/L 5.2%
of the EPA limit 15 pCi/L
worst single sample: 0.8000 pCi/L
2/2 SYR4 2019
Dibromochloromethane
0.5300 µg/L
No EPA limit set
1/6 SYR4 2012–2017
95 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCopperCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneFluorideGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
GRIFFIN, BOBBY
Phone
205-429-2495
Email
[email protected]

Frequently asked questions about Blountsville, the Ub of the Town of

Is Blountsville, the Ub of the Town of tap water safe to drink?

EPA monitoring detected 9 contaminants in Blountsville, the Ub of the Town of's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Blountsville, the Ub of the Town of's water?

EPA monitoring detected Nitrate, Lead, Nitrate-Nitrite, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does Blountsville, the Ub of the Town of serve?

Blountsville, the Ub of the Town of reports serving 4,266 people in Alabama, per its EPA record.

Has Blountsville, the Ub of the Town of had any water quality violations?

The EPA has 14 violations on file for Blountsville, the Ub of the Town of, of which 4 are health-based (a contaminant limit or required treatment was breached) and 3 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.