← Alabama

Tap water quality report

Summerdale, Ww Board of the Town of

EPA monitoring tested this supplier for 74 contaminants and detected 17. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

74
contaminants tested
17
detected
1,800
people served
12
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Baldwin

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

12
health-based violations
14
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2011-01-01 → 2011-03-31
MCL Health-based Resolved 2011-01-01 → 2011-03-31
MCL Health-based Resolved 2011-01-01 → 2011-03-31
MCL Health-based Resolved 2011-01-01 → 2011-03-31
MCL Health-based Resolved 2011-01-01 → 2013-12-31
MCL Health-based Resolved 2011-01-01 → 2013-12-31
MCL Health-based Resolved 2011-01-01 → 2013-12-31
MCL Health-based Resolved 2011-01-01 → 2013-12-31
MCL Health-based Resolved 2007-07-01 → 2007-07-31
MCL Health-based Resolved 2007-07-01 → 2007-07-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
5350 µg/L 54%
of the EPA limit 10000 µg/L
worst single sample: 5490 µg/L
68/68 SYR4 2012–2019
Nitrate-Nitrite
5350 µg/L 54%
of the EPA limit 10000 µg/L
worst single sample: 5490 µg/L
31/31 SYR4 2012–2019
Lead
0.0076 mg/L 51%
of the EPA limit 0.0150 mg/L
18/18 LCR 2023
Ethylene Dibromide
0.1850 µg/L 370%
of the EPA limit, at the 95th percentile of samples — 0.0500 µg/L
worst single sample: 0.1930 µg/L
17/49 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
7.545 µg/L 13%
of the EPA limit 60 µg/L
worst single sample: 13.98 µg/L
14/15 SYR4 2012–2019
TTHM
11.455 µg/L 14%
of the EPA limit 80 µg/L
worst single sample: 11.5 µg/L
10/15 SYR4 2012–2019
Gross Alpha, Excl. Radon And U
5.359 pCi/L 36%
of the EPA limit 15 pCi/L
worst single sample: 5.59 pCi/L
4/4 SYR4 2013–2018
Copper
3870.19 µg/L 298%
of the EPA limit, at the 95th percentile of samples — 1300 µg/L
worst single sample: 4290 µg/L
3/3 SYR4 2013–2019
Fluoride
37.7 µg/L 0.9%
of the EPA limit 4000 µg/L
worst single sample: 40 µg/L
3/3 SYR4 2013–2019
Lead
6.4372 µg/L 43%
of the EPA limit 15 µg/L
worst single sample: 7.07 µg/L
3/3 SYR4 2013–2019
Barium
140.35 µg/L 7%
of the EPA limit 2000 µg/L
worst single sample: 141 µg/L
2/3 SYR4 2013–2019
Chromium
0.6575 µg/L 0.7%
of the EPA limit 100 µg/L
worst single sample: 0.6630 µg/L
2/3 SYR4 2013–2019
Nitrite
3.9 µg/L 0.4%
of the EPA limit 1000 µg/L
worst single sample: 4 µg/L
2/31 SYR4 2012–2019
Atrazine
0.0400 µg/L 1.3%
of the EPA limit 3 µg/L
1/3 SYR4 2014–2019
Chloroform
0.5400 µg/L
No EPA limit set
1/3 SYR4 2014–2017
Mercury
0.1820 µg/L 9.1%
of the EPA limit 2 µg/L
1/3 SYR4 2013–2019
Thallium, Total
3.25 µg/L 163%
of the EPA limit, at the 95th percentile of samples — 2 µg/L
1/3 SYR4 2013–2019
57 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromochloromethaneDinosebDiquatEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMethoxychlorOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
FARRIS, RANDY
Phone
251-989-6202
Email
[email protected]

Frequently asked questions about Summerdale, Ww Board of the Town of

Is Summerdale, Ww Board of the Town of tap water safe to drink?

EPA monitoring detected 17 contaminants in Summerdale, Ww Board of the Town of's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Summerdale, Ww Board of the Town of's water?

EPA monitoring detected Nitrate, Nitrate-Nitrite, Lead, Ethylene Dibromide, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does Summerdale, Ww Board of the Town of serve?

Summerdale, Ww Board of the Town of reports serving 1,800 people in Alabama, per its EPA record.

Has Summerdale, Ww Board of the Town of had any water quality violations?

The EPA has 14 violations on file for Summerdale, Ww Board of the Town of, of which 12 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.