Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Archived | 2025-12-01 → 2025-12-31 |
| TT | Health-based | Archived | 2025-12-01 → 2025-12-31 |
| TT | Health-based | Archived | 2025-11-01 → 2025-11-30 |
| TT | Health-based | Resolved | 2025-07-01 → 2025-07-31 |
| TT | Health-based | Archived | 2025-07-01 → 2025-07-31 |
| TT | Health-based | Archived | 2025-07-01 → 2025-07-31 |
| TT | Health-based | Archived | 2025-06-01 → 2025-06-30 |
| TT | Health-based | Archived | 2025-06-01 → 2025-06-30 |
| MCL | Health-based | Archived | 2025-04-01 → 2025-06-30 |
| TT | Health-based | Resolved | 2025-01-01 → 2025-01-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 5904 µg/L 454% of the EPA limit, at the 95th percentile of samples — 1300 µg/L
worst single sample: 8130 µg/L | 69/69 | SYR4 | 2013–2019 |
| Lead | 33.375 µg/L 223% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 71.1 µg/L | 40/69 | SYR4 | 2013–2019 |
| Bromodichloromethane | 10.38 µg/L No EPA limit set
worst single sample: 15 µg/L | 25/25 | SYR4 | 2012–2019 |
| Chloroform | 91.6 µg/L No EPA limit set
worst single sample: 153 µg/L | 25/25 | SYR4 | 2012–2019 |
| TTHM | 94.2 µg/L 118% of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 157 µg/L | 25/25 | SYR4 | 2012–2019 |
| Lead | 0.0017 mg/L 11% of the EPA limit 0.0150 mg/L | 15/15 | LCR | 2023 |
| Total Haloacetic Acids (HAA5) | 21.665 µg/L 36% of the EPA limit 60 µg/L
worst single sample: 36.9 µg/L | 12/25 | SYR4 | 2012–2019 |
| Dibromochloromethane | 3.5635 µg/L No EPA limit set
worst single sample: 4.4 µg/L | 8/25 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 19.495 µg/L No EPA limit set
worst single sample: 28 µg/L | 8/25 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 7.88 µg/L No EPA limit set
worst single sample: 8.9 µg/L | 7/25 | SYR4 | 2012–2019 |
| Xylenes, Total | 0.7450 µg/L 0% of the EPA limit 10000 µg/L
worst single sample: 0.7500 µg/L | 3/10 | SYR4 | 2012–2019 |
| Nitrate-Nitrite | 200 µg/L 2% of the EPA limit 10000 µg/L | 2/14 | SYR4 | 2012–2019 |
| Barium | 22 µg/L 1.1% of the EPA limit 2000 µg/L | 1/1 | SYR4 | 2019 |
35 contaminants tested, none detected
Utility contact
Frequently asked questions about Selawik Safewater Facility
Is Selawik Safewater Facility tap water safe to drink?
EPA monitoring detected 13 contaminants in Selawik Safewater Facility's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Selawik Safewater Facility's water?
EPA monitoring detected Copper, Lead, Bromodichloromethane, Chloroform, TTHM, and others. The full list with the level and data source for each is above.
How many people does Selawik Safewater Facility serve?
Selawik Safewater Facility reports serving 846 people in Alaska, per its EPA record.
Has Selawik Safewater Facility had any water quality violations?
The EPA has 2033 violations on file for Selawik Safewater Facility, of which 456 are health-based (a contaminant limit or required treatment was breached) and 4 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.