← Alaska

Tap water quality report

Emmonak Water

EPA monitoring tested this supplier for 47 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

47
contaminants tested
14
detected
820
people served
192
health-based violations
Water source
Surface water
Ownership
Native American
Counties served
Wade Hampton Census Area

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

192
health-based violations
1,564
violations on file
6
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 2025-10-01 → 2025-12-31
MCL Health-based Archived 2025-10-01 → 2025-12-31
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2023-07-01 → 2023-09-30
TT Health-based Resolved 2023-07-01 → 2023-09-30
TT Health-based Resolved 2023-07-01 → 2023-09-30
MCL Health-based Resolved 2023-07-01 → 2023-09-30
MCL Health-based Resolved 2023-07-01 → 2023-09-30
MCL Health-based Resolved 2023-07-01 → 2023-09-30
TT Health-based Resolved 2023-06-24

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Chloroform
114 µg/L
No EPA limit set
worst single sample: 120 µg/L
30/30 SYR4 2012–2019
TTHM
115.1 µg/L 144%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 122 µg/L
30/30 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
33.66 µg/L 56%
of the EPA limit 60 µg/L
worst single sample: 40 µg/L
29/30 SYR4 2012–2019
Bromodichloromethane
4.545 µg/L
No EPA limit set
worst single sample: 4.9 µg/L
28/30 SYR4 2012–2019
Dichloroacetic Acid
7.785 µg/L
No EPA limit set
worst single sample: 17 µg/L
28/30 SYR4 2012–2019
Trichloroacetic Acid
27.18 µg/L
No EPA limit set
worst single sample: 29 µg/L
28/30 SYR4 2012–2019
Copper
767.35 µg/L 59%
of the EPA limit 1300 µg/L
worst single sample: 950 µg/L
14/14 SYR4 2012–2018
Nitrate-Nitrite
314 µg/L 3.1%
of the EPA limit 10000 µg/L
12/16 SYR4 2012–2019
Lead
0.00094 mg/L 6.3%
of the EPA limit 0.0150 mg/L
11/11 LCR 2021
Lead
7.97 µg/L 53%
of the EPA limit 15 µg/L
worst single sample: 8.57 µg/L
3/14 SYR4 2012–2018
Antimony, Total
0.1050 µg/L 1.7%
of the EPA limit 6 µg/L
1/1 SYR4 2012
Barium
53.4 µg/L 2.7%
of the EPA limit 2000 µg/L
1/1 SYR4 2013
Chromium
0.5090 µg/L 0.5%
of the EPA limit 100 µg/L
1/1 SYR4 2013
Selenium
1.06 µg/L 2.1%
of the EPA limit 50 µg/L
1/1 SYR4 2013
33 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-DichloropropaneBenzeneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbon TetrachlorideCombined Radium (-226 And -228)DichloromethaneDibromoacetic AcidDibromochloromethaneEthylbenzeneFluorideMercuryMonobromoacetic AcidMonochloroacetic AcidStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
ROLAND, DAVE
Phone
907-949-1227
Email
[email protected]

Frequently asked questions about Emmonak Water

Is Emmonak Water tap water safe to drink?

EPA monitoring detected 14 contaminants in Emmonak Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Emmonak Water's water?

EPA monitoring detected Chloroform, TTHM, Total Haloacetic Acids (HAA5), Bromodichloromethane, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Emmonak Water serve?

Emmonak Water reports serving 820 people in Alaska, per its EPA record.

Has Emmonak Water had any water quality violations?

The EPA has 1564 violations on file for Emmonak Water, of which 192 are health-based (a contaminant limit or required treatment was breached) and 6 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.