Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Archived | 1996-08-01 → 1996-08-31 |
| MCL | Health-based | Archived | 1996-08-01 → 1996-08-31 |
| MR | Monitoring | Resolved | 2026-01-01 |
| MR | Monitoring | Resolved | 2024-09-01 → 2024-09-30 |
| MR | Monitoring | Resolved | 2024-01-01 → 2024-03-31 |
| MR | Monitoring | Resolved | 2023-10-01 → 2023-12-31 |
| MR | Monitoring | Resolved | 2010-04-01 → 2010-06-30 |
| MR | Monitoring | Archived | 2003-06-01 → 2003-06-30 |
| MR | Monitoring | Archived | 2001-08-01 → 2001-08-31 |
| MR | Monitoring | Resolved | 2001-07-30 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 150 µg/L 12% of the EPA limit 1300 µg/L
worst single sample: 163 µg/L | 30/30 | SYR4 | 2013–2019 |
| Lead | 0.0018 mg/L 12% of the EPA limit 0.0150 mg/L | 17/17 | LCR | 2028 |
| Lead | 25.36 µg/L 169% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 32.8 µg/L | 17/30 | SYR4 | 2013–2019 |
| Nitrate-Nitrite | 7798 µg/L 78% of the EPA limit 10000 µg/L
worst single sample: 7980 µg/L | 8/8 | SYR4 | 2012–2019 |
| TTHM | 10.29 µg/L 13% of the EPA limit 80 µg/L
worst single sample: 11 µg/L | 3/3 | SYR4 | 2018–2019 |
| Bromodichloromethane | 2.145 µg/L No EPA limit set
worst single sample: 2.2 µg/L | 2/3 | SYR4 | 2018–2019 |
| Dibromochloromethane | 2.08 µg/L No EPA limit set
worst single sample: 2.1 µg/L | 2/3 | SYR4 | 2018–2019 |
| Nitrate | 7260 µg/L 73% of the EPA limit 10000 µg/L | 2/2 | SYR4 | 2017 |
| Arsenic | 0.7510 µg/L 7.5% of the EPA limit 10 µg/L | 1/1 | SYR4 | 2013 |
| Barium | 9 µg/L 0.5% of the EPA limit 2000 µg/L | 1/1 | SYR4 | 2019 |
| Bromoform | 0.5100 µg/L No EPA limit set | 1/3 | SYR4 | 2018–2019 |
| Chloroform | 5.8 µg/L No EPA limit set | 1/3 | SYR4 | 2018–2019 |
| Chromium | 2.2 µg/L 2.2% of the EPA limit 100 µg/L | 1/1 | SYR4 | 2019 |
36 contaminants tested, none detected
Utility contact
Frequently asked questions about Unified Alaskan Utilities-Homestead Div.
Is Unified Alaskan Utilities-Homestead Div. tap water safe to drink?
EPA monitoring detected 13 contaminants in Unified Alaskan Utilities-Homestead Div.'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Unified Alaskan Utilities-Homestead Div.'s water?
EPA monitoring detected Copper, Lead, Lead, Nitrate-Nitrite, TTHM, and others. The full list with the level and data source for each is above.
How many people does Unified Alaskan Utilities-Homestead Div. serve?
Unified Alaskan Utilities-Homestead Div. reports serving 708 people in Alaska, per its EPA record.
Has Unified Alaskan Utilities-Homestead Div. had any water quality violations?
The EPA has 300 violations on file for Unified Alaskan Utilities-Homestead Div., of which 2 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.