← Alaska

Tap water quality report

Moa Municipality of Anchorage

EPA monitoring tested this supplier for 80 contaminants and detected 26. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

80
contaminants tested
26
detected
221,351
people served
0
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Anchorage Municipality

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
425
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2025-01-31
MR Monitoring Resolved 2022-05-01 → 2022-07-31
MR Monitoring Resolved 2022-05-01 → 2022-07-31
MR Monitoring Archived 2019-07-01 → 2019-09-30
MR Monitoring Archived 2019-01-01 → 2019-03-31
MR Monitoring Resolved 2018-01-01 → 2018-03-31
MR Monitoring Resolved 2017-11-01 → 2018-01-31
MR Monitoring Resolved 2017-11-01 → 2018-01-31
MR Monitoring Resolved 2016-01-01 → 2016-12-31
Other Monitoring Resolved 2011-07-01

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
PFHXS 0.0112 µg/L 4/24 2023
PFOA 0.0091 µg/L 1/24 2023

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Chloroform
20.975 µg/L
No EPA limit set
worst single sample: 66.8 µg/L
248/254 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
10.9 µg/L 18%
of the EPA limit 60 µg/L
worst single sample: 74 µg/L
231/255 SYR4 2012–2019
Dichloroacetic Acid
6.944 µg/L
No EPA limit set
worst single sample: 34 µg/L
225/255 SYR4 2012–2019
TTHM
22.7 µg/L 28%
of the EPA limit 80 µg/L
worst single sample: 68.3 µg/L
221/254 SYR4 2012–2019
Trichloroacetic Acid
3.83 µg/L
No EPA limit set
worst single sample: 40 µg/L
221/255 SYR4 2012–2019
Copper
89.1 µg/L 6.9%
of the EPA limit 1300 µg/L
worst single sample: 212 µg/L
199/222 SYR4 2012–2019
Bromodichloromethane
1.1 µg/L
No EPA limit set
worst single sample: 1.45 µg/L
156/254 SYR4 2012–2019
Barium
90.1 µg/L 4.5%
of the EPA limit 2000 µg/L
worst single sample: 100 µg/L
90/90 SYR4 2012–2019
Nitrate-Nitrite
1477.5 µg/L 15%
of the EPA limit 10000 µg/L
worst single sample: 1810 µg/L
82/93 SYR4 2012–2019
Chromium
1.868 µg/L 1.9%
of the EPA limit 100 µg/L
worst single sample: 2.8 µg/L
52/90 SYR4 2012–2019
Lead
3.4175 µg/L 23%
of the EPA limit 15 µg/L
worst single sample: 32 µg/L
46/241 SYR4 2012–2019
Nitrate
1576 µg/L 16%
of the EPA limit 10000 µg/L
worst single sample: 1690 µg/L
40/46 SYR4 2016–2019
Fluoride
615.4 µg/L 15%
of the EPA limit 4000 µg/L
worst single sample: 660 µg/L
34/91 SYR4 2012–2019
Arsenic
2.172 µg/L 22%
of the EPA limit 10 µg/L
worst single sample: 2.2 µg/L
29/89 SYR4 2012–2019
Selenium
1.901 µg/L 3.8%
of the EPA limit 50 µg/L
worst single sample: 2.3 µg/L
15/90 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
13/13 LCR 2024
Monochloroacetic Acid
5.6485 µg/L
No EPA limit set
worst single sample: 5.89 µg/L
8/255 SYR4 2012–2019
Antimony, Total
0.1821 µg/L 3%
of the EPA limit 6 µg/L
worst single sample: 0.1860 µg/L
4/90 SYR4 2012–2019
Dibromochloromethane
1.2 µg/L
No EPA limit set
worst single sample: 1.23 µg/L
2/254 SYR4 2012–2019
Beryllium, Total
0.3010 µg/L 7.5%
of the EPA limit 4 µg/L
1/90 SYR4 2012–2019
Cyanide
6.3 µg/L 3.2%
of the EPA limit 200 µg/L
1/78 SYR4 2012–2019
Combined Radium (-226 And -228)
1.5 pCi/L 30%
of the EPA limit 5 pCi/L
1/15 SYR4 2016–2019
Monobromoacetic Acid
1.2 µg/L
No EPA limit set
1/255 SYR4 2012–2019
Toluene
0.8200 µg/L 0.1%
of the EPA limit 1000 µg/L
1/91 SYR4 2012–2019
54 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaBenzeneBromoformChlorobenzeneCadmiumCarbon TetrachlorideDichloromethaneDibromoacetic AcidEthylbenzeneHfpo-DaMercuryNetfosaaNfdhaNmefosaaNitritePfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPfmbaPfmpaPFNAPFOSPfpeaPfpesPftaPftrdaPfunaStyreneTetrachloroethyleneThallium, TotalTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
SMITH, PAUL
Phone
907-751-2212
Email
[email protected]

Frequently asked questions about Moa Municipality of Anchorage

Is Moa Municipality of Anchorage tap water safe to drink?

EPA monitoring detected 26 contaminants in Moa Municipality of Anchorage's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Moa Municipality of Anchorage's water?

EPA monitoring detected Chloroform, Total Haloacetic Acids (HAA5), Dichloroacetic Acid, TTHM, Trichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Moa Municipality of Anchorage serve?

Moa Municipality of Anchorage reports serving 221,351 people in Alaska, per its EPA record.

Has Moa Municipality of Anchorage had any water quality violations?

The EPA has 425 violations on file for Moa Municipality of Anchorage, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.