← Wyoming

Tap water quality report

Ethete Water

EPA monitoring tested this supplier for 80 contaminants and detected 16. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

80
contaminants tested
16
detected
1,950
people served
31
health-based violations
Water source
Surface water
Ownership
Native American

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

31
health-based violations
632
violations on file
1
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2025-06-01 → 2025-06-30
TT Health-based Resolved 2025-06-01 → 2025-06-30
TT Health-based Resolved 2020-11-01 → 2020-11-30
TT Health-based Resolved 2020-11-01 → 2020-11-30
TT Health-based Resolved 2019-06-23
TT Health-based Resolved 2019-06-23
TT Health-based Resolved 2018-07-01
TT Health-based Resolved 2018-07-01
TT Health-based Resolved 2016-03-01 → 2016-03-31
TT Health-based Resolved 2016-03-01 → 2016-03-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
50.75 µg/L 63%
of the EPA limit 80 µg/L
worst single sample: 57 µg/L
66/66 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
53.95 µg/L 90%
of the EPA limit 60 µg/L
worst single sample: 58 µg/L
62/62 SYR4 2012–2019
Bromodichloromethane
5.605 µg/L
No EPA limit set
worst single sample: 6.9 µg/L
54/54 SYR4 2013–2019
Chloroform
46.7 µg/L
No EPA limit set
worst single sample: 53 µg/L
54/54 SYR4 2013–2019
Dichloroacetic Acid
23 µg/L
No EPA limit set
worst single sample: 24 µg/L
49/49 SYR4 2013–2019
Trichloroacetic Acid
31.6 µg/L
No EPA limit set
worst single sample: 36 µg/L
49/49 SYR4 2013–2019
Copper
676.7 µg/L 52%
of the EPA limit 1300 µg/L
worst single sample: 8520 µg/L
47/52 SYR4 2015–2019
Lead
0.0010 mg/L 6.7%
of the EPA limit 0.0150 mg/L
17/17 LCR 2025
Monochloroacetic Acid
1.75 µg/L
No EPA limit set
worst single sample: 1.9 µg/L
16/49 SYR4 2013–2019
Dibromochloromethane
1.335 µg/L
No EPA limit set
worst single sample: 1.4 µg/L
14/54 SYR4 2013–2019
Lead
12.8 µg/L 85%
of the EPA limit 15 µg/L
worst single sample: 20 µg/L
10/52 SYR4 2015–2019
Nitrate-Nitrite
29.5 µg/L 0.3%
of the EPA limit 10000 µg/L
worst single sample: 30 µg/L
2/7 SYR4 2012–2019
Combined Radium (-226 And -228)
0.5000 pCi/L 10%
of the EPA limit 5 pCi/L
1/2 SYR4 2012–2018
Combined Uranium
1 µg/L 3.3%
of the EPA limit 30 µg/L
1/2 SYR4 2012–2018
Dibromoacetic Acid
0.4200 µg/L
No EPA limit set
1/49 SYR4 2013–2019
Gross Alpha, Excl. Radon And U
1.3 pCi/L 8.7%
of the EPA limit 15 pCi/L
1/2 SYR4 2012–2018
64 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneFluorideGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidNitrateOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
HARJO, BRENDEN
Email
[email protected]

Frequently asked questions about Ethete Water

Is Ethete Water tap water safe to drink?

EPA monitoring detected 16 contaminants in Ethete Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Ethete Water's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Bromodichloromethane, Chloroform, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Ethete Water serve?

Ethete Water reports serving 1,950 people in Wyoming, per its EPA record.

Has Ethete Water had any water quality violations?

The EPA has 632 violations on file for Ethete Water, of which 31 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.