← Montana

Tap water quality report

Chief Martin Charlo Homesite

EPA monitoring tested this supplier for 76 contaminants and detected 11. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

76
contaminants tested
11
detected
66
people served
0
health-based violations
Water source
Ground water
Ownership
Native American

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
1
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2023-10-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.0030 mg/L 20%
of the EPA limit 0.0150 mg/L
6/6 LCR 2023
Nitrate
1280 µg/L 13%
of the EPA limit 10000 µg/L
6/6 SYR4 2013–2018
Nitrate-Nitrite
1565 µg/L 16%
of the EPA limit 10000 µg/L
worst single sample: 1660 µg/L
6/7 SYR4 2013–2019
Copper
66 µg/L 5.1%
of the EPA limit 1300 µg/L
worst single sample: 70 µg/L
5/5 SYR4 2017
Barium
330 µg/L 17%
of the EPA limit 2000 µg/L
4/4 SYR4 2013–2018
Gross Alpha, Excl. Radon And U
2.585 pCi/L 17%
of the EPA limit 15 pCi/L
worst single sample: 2.6 pCi/L
4/6 SYR4 2013–2019
Combined Radium (-226 And -228)
2.75 pCi/L 55%
of the EPA limit 5 pCi/L
worst single sample: 3 pCi/L
3/6 SYR4 2013–2019
Fluoride
40 µg/L 1%
of the EPA limit 4000 µg/L
3/3 SYR4 2013–2018
Combined Uranium
0.6000 µg/L 2%
of the EPA limit 30 µg/L
1/8 SYR4 2013–2019
Di(2-ethylhexyl) Phthalate
1.1 µg/L 18%
of the EPA limit 6 µg/L
1/8 SYR4 2013–2018
Lead
1 µg/L 6.7%
of the EPA limit 15 µg/L
1/5 SYR4 2017
65 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDibromochloromethaneDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTTHMTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
PHILLIPS, REBECCA
Phone
406-675-4491
Email
[email protected]

Frequently asked questions about Chief Martin Charlo Homesite

Is Chief Martin Charlo Homesite tap water safe to drink?

EPA monitoring detected 11 contaminants in Chief Martin Charlo Homesite's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Chief Martin Charlo Homesite's water?

EPA monitoring detected Lead, Nitrate, Nitrate-Nitrite, Copper, Barium, and others. The full list with the level and data source for each is above.

How many people does Chief Martin Charlo Homesite serve?

Chief Martin Charlo Homesite reports serving 66 people in Montana, per its EPA record.

Has Chief Martin Charlo Homesite had any water quality violations?

The EPA has 1 violation on file for Chief Martin Charlo Homesite, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.