← Montana

Tap water quality report

Dixon (Old Agency)

EPA monitoring tested this supplier for 82 contaminants and detected 17. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

82
contaminants tested
17
detected
72
people served
12
health-based violations
Water source
Ground water
Ownership
Native American

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

12
health-based violations
27
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2018-01-01 → 2018-03-31
MCL Health-based Resolved 2017-10-01 → 2017-12-31
MCL Health-based Resolved 2017-07-01 → 2017-09-30
MCL Health-based Resolved 2013-04-01 → 2013-06-30
MCL Health-based Resolved 2013-01-01 → 2013-03-31
MCL Health-based Resolved 2008-01-01 → 2008-12-31
MCL Health-based Resolved 2007-01-01 → 2007-12-31
MCL Health-based Resolved 2007-01-01 → 2007-12-31
MCL Health-based Archived 2001-12-01 → 2001-12-31
MCL Health-based Archived 2001-11-01 → 2001-11-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Arsenic
21.875 µg/L 219%
of the EPA limit, at the 95th percentile of samples — 10 µg/L
worst single sample: 24 µg/L
30/31 SYR4 2012–2019
Copper
180.5 µg/L 14%
of the EPA limit 1300 µg/L
worst single sample: 330 µg/L
14/14 SYR4 2018–2019
Lead
0.0100 mg/L 67%
of the EPA limit 0.0150 mg/L
10/10 LCR 2025
Combined Radium (-226 And -228)
3.1 pCi/L 62%
of the EPA limit 5 pCi/L
6/6 SYR4 2016–2019
Combined Uranium
3.1 µg/L 10%
of the EPA limit 30 µg/L
5/6 SYR4 2016–2019
Gross Alpha, Excl. Radon And U
1.68 pCi/L 11%
of the EPA limit 15 pCi/L
worst single sample: 1.7 pCi/L
5/6 SYR4 2016–2019
Lead
2.85 µg/L 19%
of the EPA limit 15 µg/L
worst single sample: 3 µg/L
4/14 SYR4 2018–2019
TTHM
0.9460 µg/L 1.2%
of the EPA limit 80 µg/L
worst single sample: 1 µg/L
4/10 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
1.6 µg/L 2.7%
of the EPA limit 60 µg/L
3/4 SYR4 2013–2018
Dibromoacetic Acid
0.9120 µg/L
No EPA limit set
worst single sample: 0.9400 µg/L
2/4 SYR4 2013–2018
Nitrate
130 µg/L 1.3%
of the EPA limit 10000 µg/L
2/4 SYR4 2017–2018
Nitrate-Nitrite
158.5 µg/L 1.6%
of the EPA limit 10000 µg/L
worst single sample: 160 µg/L
2/9 SYR4 2012–2019
Barium
200 µg/L 10%
of the EPA limit 2000 µg/L
1/1 SYR4 2018
Bromoform
0.5700 µg/L
No EPA limit set
1/10 SYR4 2013–2019
Dichloroacetic Acid
0.7800 µg/L
No EPA limit set
1/4 SYR4 2013–2018
Fluoride
280 µg/L 7%
of the EPA limit 4000 µg/L
1/1 SYR4 2018
Monochloroacetic Acid
1.4 µg/L
No EPA limit set
1/4 SYR4 2013–2018
65 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromochloromethaneDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
PHILLIPS, REBECCA
Phone
406-675-4491
Email
[email protected]

Frequently asked questions about Dixon (Old Agency)

Is Dixon (Old Agency) tap water safe to drink?

EPA monitoring detected 17 contaminants in Dixon (Old Agency)'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Dixon (Old Agency)'s water?

EPA monitoring detected Arsenic, Copper, Lead, Combined Radium (-226 And -228), Combined Uranium, and others. The full list with the level and data source for each is above.

How many people does Dixon (Old Agency) serve?

Dixon (Old Agency) reports serving 72 people in Montana, per its EPA record.

Has Dixon (Old Agency) had any water quality violations?

The EPA has 27 violations on file for Dixon (Old Agency), of which 12 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.