Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2022-04-01 → 2022-06-30 |
| MCL | Health-based | Resolved | 2022-04-01 → 2022-06-30 |
| MCL | Health-based | Resolved | 2022-04-01 → 2022-06-30 |
| MCL | Health-based | Resolved | 2022-04-01 → 2022-06-30 |
| MCL | Health-based | Resolved | 2022-04-01 → 2022-06-30 |
| MCL | Health-based | Resolved | 2022-04-01 → 2022-06-30 |
| MCL | Health-based | Resolved | 2022-01-01 → 2022-03-31 |
| MCL | Health-based | Resolved | 2022-01-01 → 2022-03-31 |
| MCL | Health-based | Resolved | 2022-01-01 → 2022-03-31 |
| MCL | Health-based | Resolved | 2022-01-01 → 2022-03-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| TTHM | 221.633 µg/L 277% of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 245 µg/L | 58/58 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 73.855 µg/L 123% of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 119 µg/L | 58/58 | SYR4 | 2012–2019 |
| Bromodichloromethane | 27.36 µg/L No EPA limit set
worst single sample: 42.7 µg/L | 57/57 | SYR4 | 2012–2019 |
| Chloroform | 175.8 µg/L No EPA limit set
worst single sample: 212 µg/L | 57/57 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 35.28 µg/L No EPA limit set
worst single sample: 62.8 µg/L | 57/57 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 41.5 µg/L No EPA limit set
worst single sample: 58.8 µg/L | 56/57 | SYR4 | 2012–2019 |
| Dibromochloromethane | 7.306 µg/L No EPA limit set
worst single sample: 8.52 µg/L | 53/57 | SYR4 | 2012–2019 |
| Copper | 1281 µg/L 99% of the EPA limit 1300 µg/L
worst single sample: 1370 µg/L | 30/30 | SYR4 | 2013–2019 |
| Lead | 6.45 µg/L 43% of the EPA limit 15 µg/L
worst single sample: 7.1 µg/L | 14/30 | SYR4 | 2013–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 9/9 | LCR | 2022 |
| Monochloroacetic Acid | 7.32 µg/L No EPA limit set
worst single sample: 7.96 µg/L | 9/57 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 1.534 µg/L No EPA limit set
worst single sample: 1.54 µg/L | 5/57 | SYR4 | 2012–2019 |
2 contaminants tested, none detected
Utility contact
Frequently asked questions about Jones Academy
Is Jones Academy tap water safe to drink?
EPA monitoring detected 12 contaminants in Jones Academy's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Jones Academy's water?
EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Bromodichloromethane, Chloroform, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.
How many people does Jones Academy serve?
Jones Academy reports serving 290 people in Oklahoma, per its EPA record.
Has Jones Academy had any water quality violations?
The EPA has 153 violations on file for Jones Academy, of which 146 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.