← Wisconsin

Tap water quality report

South-Central Water

EPA monitoring tested this supplier for 100 contaminants and detected 11. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

100
contaminants tested
11
detected
2,805
people served
0
health-based violations
Water source
Ground water
Ownership
Native American

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
20
violations on file
0
still open
ViolationTypeStatusPeriod
RPT Monitoring Resolved 2023-08-01
RPT Monitoring Resolved 2023-08-01
RPT Monitoring Resolved 2023-08-01
RPT Monitoring Resolved 2023-08-01
MR Monitoring Resolved 2019-01-01 → 2019-12-31
MR Monitoring Resolved 2019-01-01 → 2019-12-31
MR Monitoring Resolved 2019-01-01 → 2019-12-31
MON Monitoring Resolved 2018-05-01 → 2018-05-31
MON Monitoring Resolved 2018-05-01 → 2018-05-31
MON Monitoring Resolved 2018-05-01 → 2018-05-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
601.5 µg/L 46%
of the EPA limit 1300 µg/L
worst single sample: 870 µg/L
30/30 SYR4 2013–2019
Lead
10.795 µg/L 72%
of the EPA limit 15 µg/L
worst single sample: 35 µg/L
30/30 SYR4 2013–2019
Nitrate
1500 µg/L 15%
of the EPA limit 10000 µg/L
16/18 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
21.8 µg/L 36%
of the EPA limit 60 µg/L
worst single sample: 23 µg/L
13/13 SYR4 2012–2019
TTHM
32 µg/L 40%
of the EPA limit 80 µg/L
worst single sample: 33 µg/L
11/11 SYR4 2012–2019
Lead
0.0040 mg/L 27%
of the EPA limit 0.0150 mg/L
9/9 LCR 2025
Fluoride
308 µg/L 7.7%
of the EPA limit 4000 µg/L
worst single sample: 310 µg/L
3/3 SYR4 2012–2019
Barium
17 µg/L 0.9%
of the EPA limit 2000 µg/L
2/3 SYR4 2012–2019
Antimony, Total
0.9100 µg/L 15%
of the EPA limit 6 µg/L
1/3 SYR4 2012–2019
Chromium
0.7500 µg/L 0.8%
of the EPA limit 100 µg/L
1/3 SYR4 2012–2019
Nitrate-Nitrite
1400 µg/L 14%
of the EPA limit 10000 µg/L
1/3 SYR4 2012–2014
89 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
LAMERE, KELLY D
Phone
715-793-3028
Email
[email protected]

Frequently asked questions about South-Central Water

Is South-Central Water tap water safe to drink?

EPA monitoring detected 11 contaminants in South-Central Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in South-Central Water's water?

EPA monitoring detected Copper, Lead, Nitrate, Total Haloacetic Acids (HAA5), TTHM, and others. The full list with the level and data source for each is above.

How many people does South-Central Water serve?

South-Central Water reports serving 2,805 people in Wisconsin, per its EPA record.

Has South-Central Water had any water quality violations?

The EPA has 20 violations on file for South-Central Water, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.