← West Virginia

Tap water quality report

Belva, WV

EPA monitoring detected 14 contaminants across the 1 water supplier serving Belva. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier for each below, with its EPA source and period.

1
water supplier
3,944
people served
14
contaminants found

What was found in Belva's water

The level at the city's main supplier, the highest level anywhere in the city, the EPA limit for each, and where every figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Copper
309.6 µg/L 24%
of the EPA limit 1300 µg/L
Main supplier: GAULEY RIVER PSD · 3,944 people · 2017
1/1 SYR4
Lead
96.85 µg/L 646%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
Main supplier: GAULEY RIVER PSD · 3,944 people · 2017
1/1 SYR4
TTHM
84.015 µg/L 105%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
Main supplier: GAULEY RIVER PSD · 3,944 people · 2019
1/1 SYR4
Total Haloacetic Acids (HAA5)
82.29 µg/L 137%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
Main supplier: GAULEY RIVER PSD · 3,944 people · 2019
1/1 SYR4
Chloroform
75.69 µg/L
No EPA limit set
Main supplier: GAULEY RIVER PSD · 3,944 people · 2019
1/1 SYR4
Trichloroacetic Acid
46.155 µg/L
No EPA limit set
Main supplier: GAULEY RIVER PSD · 3,944 people · 2019
1/1 SYR4
Dichloroacetic Acid
33.72 µg/L
No EPA limit set
Main supplier: GAULEY RIVER PSD · 3,944 people · 2019
1/1 SYR4
Bromodichloromethane
9.575 µg/L
No EPA limit set
Main supplier: GAULEY RIVER PSD · 3,944 people · 2019
1/1 SYR4
Monochloroacetic Acid
5.12 µg/L
No EPA limit set
Main supplier: GAULEY RIVER PSD · 3,944 people · 2019
1/1 SYR4
Monobromoacetic Acid
3.595 µg/L
No EPA limit set
Main supplier: GAULEY RIVER PSD · 3,944 people · 2019
1/1 SYR4
Dibromochloromethane
1.475 µg/L
No EPA limit set
Main supplier: GAULEY RIVER PSD · 3,944 people · 2019
1/1 SYR4
Bromoform
0.7000 µg/L
No EPA limit set
Main supplier: GAULEY RIVER PSD · 3,944 people · 2019
1/1 SYR4
Dibromoacetic Acid
0.5770 µg/L
No EPA limit set
Main supplier: GAULEY RIVER PSD · 3,944 people · 2019
1/1 SYR4
Lead
0.00065 mg/L 4.3%
of the EPA limit 0.0150 mg/L
Main supplier: GAULEY RIVER PSD · 3,944 people · 2025
1/1 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Belva

SupplierPopulation served
GAULEY RIVER PSD 3,944

Frequently asked questions about Belva tap water

Is Belva tap water safe to drink?

EPA testing detected 14 contaminants in the water serving Belva. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Belva?

1 public water supplier report drinking-water monitoring for Belva, West Virginia to the EPA. Each is listed above with its population served.

What contaminants are in Belva's water?

The contaminants EPA monitoring detected in Belva include Copper, Lead, TTHM, Total Haloacetic Acids (HAA5), Chloroform. The full list, with the level at the main supplier and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.