What was found in Jackson's water
The level at the city's main supplier, the highest level anywhere in the city, the EPA limit for each, and where every figure comes from.
| Contaminant | Level vs EPA limit | Suppliers | Source |
|---|---|---|---|
| Nitrate | 2157 µg/L 22% of the EPA limit 10000 µg/L Main supplier: JACKSON WATER SYSTEM · 91,111 people · 2019 | 2/2 | SYR4 |
| Nitrate-Nitrite | 2090 µg/L 21% of the EPA limit 10000 µg/L Main supplier: JACKSON WATER SYSTEM · 91,111 people · 2019 | 1/2 | SYR4 |
| Fluoride | 765.85 µg/L 19% of the EPA limit 4000 µg/L Main supplier: JACKSON WATER SYSTEM · 91,111 people · 2017 | 1/2 | SYR4 |
| Barium | 49.55 µg/L 2.5% of the EPA limit 2000 µg/L Main supplier: JACKSON WATER SYSTEM · 91,111 people · 2017 | 1/2 | SYR4 |
| TTHM | 33.455 µg/L 42% of the EPA limit 80 µg/L Main supplier: JACKSON WATER SYSTEM · 91,111 people · 2019 | 2/2 | SYR4 |
| Total Haloacetic Acids (HAA5) | 26.1951 µg/L 44% of the EPA limit 60 µg/L Main supplier: JACKSON WATER SYSTEM · 91,111 people · 2019 | 2/2 | SYR4 |
| Tetrachloroethylene | 7.84 µg/L 157% of the EPA limit, at the 95th percentile of samples — 5 µg/L Main supplier: JACKSON WATER SYSTEM · 91,111 people · 2019 | 1/2 | SYR4 |
| Benzene | 7.5325 µg/L 151% of the EPA limit, at the 95th percentile of samples — 5 µg/L Main supplier: JACKSON WATER SYSTEM · 91,111 people · 2019 | 1/2 | SYR4 |
| Toluene | 1.13105 µg/L 0.1% of the EPA limit 1000 µg/L Main supplier: JACKSON WATER SYSTEM · 91,111 people · 2019 | 1/2 | SYR4 |
| Gross Alpha, Excl. Radon And U | 1.1 pCi/L 7.3% of the EPA limit 15 pCi/L Main supplier: JACKSON WATER SYSTEM · 91,111 people · 2014 | 1/2 | SYR4 |
| Xylenes, Total | 0.6820 µg/L 0% of the EPA limit 10000 µg/L Main supplier: JACKSON WATER SYSTEM · 91,111 people · 2019 | 1/2 | SYR4 |
| PFOS | 0.0200 µg/L No EPA limit set Main supplier: JACKSON WATER SYSTEM · 91,111 people · 2024 | 1/2 | UCMR-5 |
| PFHXS | 0.0163 µg/L No EPA limit set Main supplier: JACKSON WATER SYSTEM · 91,111 people · 2024 | 1/2 | UCMR-5 |
| Lead | 0.00050 mg/L 3.3% of the EPA limit 0.0150 mg/L Main supplier: JACKSON WATER SYSTEM · 91,111 people · 2025
Highest in the city: 0.0044 mg/L — SALTILLO UTILITY DISTRICT · 2,216 people · 2025 | 2/2 | LCR |
| PFBS | 0.0037 µg/L No EPA limit set Main supplier: JACKSON WATER SYSTEM · 91,111 people · 2024 | 1/2 | UCMR-5 |
Water suppliers serving Jackson
| Supplier | Population served |
|---|---|
| JACKSON WATER SYSTEM | 91,111 |
| SALTILLO UTILITY DISTRICT | 2,216 |
Frequently asked questions about Jackson tap water
Is Jackson tap water safe to drink?
EPA testing detected 15 contaminants in the water serving Jackson. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.
How many water suppliers serve Jackson?
2 public water suppliers report drinking-water monitoring for Jackson, Tennessee to the EPA. Each is listed above with its population served.
What contaminants are in Jackson's water?
The contaminants EPA monitoring detected in Jackson include Nitrate, Nitrate-Nitrite, Fluoride, Barium, TTHM. The full list, with the level at the main supplier and the data source, is in the table above.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.