1
water supplier
6,600
people served
17
contaminants found

What was found in Harvey Cedars boro-1509's water

The level at the city's main supplier, the highest level anywhere in the city, the EPA limit for each, and where every figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Copper
800 µg/L 62%
of the EPA limit 1300 µg/L
Main supplier: HARVEY CEDARS WATER DEPT · 6,600 people · 2018
1/1 SYR4
Barium
100 µg/L 5%
of the EPA limit 2000 µg/L
Main supplier: HARVEY CEDARS WATER DEPT · 6,600 people · 2018
1/1 SYR4
Fluoride
100 µg/L 2.5%
of the EPA limit 4000 µg/L
Main supplier: HARVEY CEDARS WATER DEPT · 6,600 people · 2018
1/1 SYR4
Lithium
10.8 µg/L
No EPA limit set
Main supplier: HARVEY CEDARS WATER DEPT · 6,600 people · 2024
1/1 UCMR-5
Total Haloacetic Acids (HAA5)
7.3525 µg/L 12%
of the EPA limit 60 µg/L
Main supplier: HARVEY CEDARS WATER DEPT · 6,600 people · 2019
1/1 SYR4
TTHM
4.652 µg/L 5.8%
of the EPA limit 80 µg/L
Main supplier: HARVEY CEDARS WATER DEPT · 6,600 people · 2019
1/1 SYR4
Monochloroacetic Acid
4.168 µg/L
No EPA limit set
Main supplier: HARVEY CEDARS WATER DEPT · 6,600 people · 2019
1/1 SYR4
Dichloroacetic Acid
2.435 µg/L
No EPA limit set
Main supplier: HARVEY CEDARS WATER DEPT · 6,600 people · 2019
1/1 SYR4
Dibromoacetic Acid
2.397 µg/L
No EPA limit set
Main supplier: HARVEY CEDARS WATER DEPT · 6,600 people · 2019
1/1 SYR4
Chloroform
1.95 µg/L
No EPA limit set
Main supplier: HARVEY CEDARS WATER DEPT · 6,600 people · 2019
1/1 SYR4
Bromodichloromethane
1.649 µg/L
No EPA limit set
Main supplier: HARVEY CEDARS WATER DEPT · 6,600 people · 2019
1/1 SYR4
Trichloroacetic Acid
1.55 µg/L
No EPA limit set
Main supplier: HARVEY CEDARS WATER DEPT · 6,600 people · 2019
1/1 SYR4
Combined Radium (-226 And -228)
1.517 pCi/L 30%
of the EPA limit 5 pCi/L
Main supplier: HARVEY CEDARS WATER DEPT · 6,600 people · 2018
1/1 SYR4
Monobromoacetic Acid
1.2665 µg/L
No EPA limit set
Main supplier: HARVEY CEDARS WATER DEPT · 6,600 people · 2019
1/1 SYR4
Dibromochloromethane
1.1 µg/L
No EPA limit set
Main supplier: HARVEY CEDARS WATER DEPT · 6,600 people · 2019
1/1 SYR4
Lead
1 µg/L 6.7%
of the EPA limit 15 µg/L
Main supplier: HARVEY CEDARS WATER DEPT · 6,600 people · 2018
1/1 SYR4
Lead
0.0015 mg/L 9.7%
of the EPA limit 0.0150 mg/L
Main supplier: HARVEY CEDARS WATER DEPT · 6,600 people · 2024
1/1 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Harvey Cedars boro-1509

SupplierPopulation served
HARVEY CEDARS WATER DEPT 6,600

Frequently asked questions about Harvey Cedars boro-1509 tap water

Is Harvey Cedars boro-1509 tap water safe to drink?

EPA testing detected 17 contaminants in the water serving Harvey Cedars boro-1509. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Harvey Cedars boro-1509?

1 public water supplier report drinking-water monitoring for Harvey Cedars boro-1509, New Jersey to the EPA. Each is listed above with its population served.

What contaminants are in Harvey Cedars boro-1509's water?

The contaminants EPA monitoring detected in Harvey Cedars boro-1509 include Copper, Barium, Fluoride, Lithium, Total Haloacetic Acids (HAA5). The full list, with the level at the main supplier and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.