← New Jersey

Tap water quality report

Atlantic city-0102, NJ

EPA monitoring detected 37 contaminants across the 1 water supplier serving Atlantic city-0102. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier for each below, with its EPA source and period.

1
water supplier
152,415
people served
37
contaminants found

What was found in Atlantic city-0102's water

The level at the city's main supplier, the highest level anywhere in the city, the EPA limit for each, and where every figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Fluoride
1256 µg/L 31%
of the EPA limit 4000 µg/L
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2019
1/1 SYR4
Copper
353.25 µg/L 27%
of the EPA limit 1300 µg/L
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2019
1/1 SYR4
Nitrate-Nitrite
147.545 µg/L 1.5%
of the EPA limit 10000 µg/L
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2019
1/1 SYR4
Nitrate
146.45 µg/L 1.5%
of the EPA limit 10000 µg/L
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2019
1/1 SYR4
Barium
87.415 µg/L 4.4%
of the EPA limit 2000 µg/L
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2019
1/1 SYR4
TTHM
52 µg/L 65%
of the EPA limit 80 µg/L
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2019
1/1 SYR4
Nitrite
51.89 µg/L 5.2%
of the EPA limit 1000 µg/L
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2019
1/1 SYR4
Chloroform
31.955 µg/L
No EPA limit set
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2019
1/1 SYR4
Lead
17.9 µg/L 119%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2017
1/1 SYR4
Bromodichloromethane
14.81 µg/L
No EPA limit set
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2019
1/1 SYR4
Total Haloacetic Acids (HAA5)
10.872 µg/L 18%
of the EPA limit 60 µg/L
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2019
1/1 SYR4
Dibromochloromethane
6.695 µg/L
No EPA limit set
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2019
1/1 SYR4
Trichloroacetic Acid
6.509 µg/L
No EPA limit set
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2019
1/1 SYR4
Gross Alpha, Excl. Radon And U
5.6 pCi/L 37%
of the EPA limit 15 pCi/L
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2015
1/1 SYR4
Dichloroacetic Acid
5.318 µg/L
No EPA limit set
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2019
1/1 SYR4
Dichloromethane
2.6535 µg/L 53%
of the EPA limit 5 µg/L
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2019
1/1 SYR4
Chromium
1.8065 µg/L 1.8%
of the EPA limit 100 µg/L
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2019
1/1 SYR4
Selenium
1.4 µg/L 2.8%
of the EPA limit 50 µg/L
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2019
1/1 SYR4
Dibromoacetic Acid
1.398 µg/L
No EPA limit set
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2019
1/1 SYR4
Di(2-ethylhexyl) Phthalate
1.2336 µg/L 21%
of the EPA limit 6 µg/L
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2019
1/1 SYR4
Bromoform
1.165 µg/L
No EPA limit set
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2019
1/1 SYR4
Monochloroacetic Acid
1.0155 µg/L
No EPA limit set
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2019
1/1 SYR4
Xylenes, Total
0.8000 µg/L 0%
of the EPA limit 10000 µg/L
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2019
1/1 SYR4
Arsenic
0.4560 µg/L 4.6%
of the EPA limit 10 µg/L
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2019
1/1 SYR4
Monobromoacetic Acid
0.3025 µg/L
No EPA limit set
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2019
1/1 SYR4
Toluene
0.1900 µg/L 0%
of the EPA limit 1000 µg/L
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2019
1/1 SYR4
Ethylbenzene
0.1000 µg/L 0%
of the EPA limit 700 µg/L
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2019
1/1 SYR4
Mercury
0.0850 µg/L 4.3%
of the EPA limit 2 µg/L
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2019
1/1 SYR4
Thallium, Total
0.0800 µg/L 4%
of the EPA limit 2 µg/L
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2019
1/1 SYR4
Di(2-ethylhexyl) Adipate
0.0710 µg/L 0%
of the EPA limit 400 µg/L
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2019
1/1 SYR4
Beryllium, Total
0.0300 µg/L 0.8%
of the EPA limit 4 µg/L
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2019
1/1 SYR4
Cadmium
0.0200 µg/L 0.4%
of the EPA limit 5 µg/L
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2019
1/1 SYR4
PFHXS
0.0073 µg/L
No EPA limit set
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2025
1/1 UCMR-5
Pfpea
0.0057 µg/L
No EPA limit set
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2025
1/1 UCMR-5
Pfhxa
0.0053 µg/L
No EPA limit set
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2025
1/1 UCMR-5
PFOA
0.0047 µg/L
No EPA limit set
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2025
1/1 UCMR-5
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
Main supplier: ATLANTIC CITY MUA · 152,415 people · 2023
1/1 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Atlantic city-0102

SupplierPopulation served
ATLANTIC CITY MUA 152,415

Frequently asked questions about Atlantic city-0102 tap water

Is Atlantic city-0102 tap water safe to drink?

EPA testing detected 37 contaminants in the water serving Atlantic city-0102. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Atlantic city-0102?

1 public water supplier report drinking-water monitoring for Atlantic city-0102, New Jersey to the EPA. Each is listed above with its population served.

What contaminants are in Atlantic city-0102's water?

The contaminants EPA monitoring detected in Atlantic city-0102 include Fluoride, Copper, Nitrate-Nitrite, Nitrate, Barium. The full list, with the level at the main supplier and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.