← Florida

Tap water quality report

Hilliard, FL

EPA monitoring detected 25 contaminants across the 3 water suppliers serving Hilliard. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier for each below, with its EPA source and period.

3
water suppliers
3,221
people served
25
contaminants found

What was found in Hilliard's water

The level at the city's main supplier, the highest level anywhere in the city, the EPA limit for each, and where every figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Fluoride
1100 µg/L 28%
of the EPA limit 4000 µg/L
Main supplier: HILLIARD WTP · 3,036 people · 2018
3/3 SYR4
Nitrate
70 µg/L 0.7%
of the EPA limit 10000 µg/L
Main supplier: HILLIARD WTP · 3,036 people · 2019
Highest in the city: 100 µg/L — DAYSPRING SENIOR LIVING · 64 people · 2019
3/3 SYR4
TTHM
81.786 µg/L 102%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
Main supplier: HILLIARD WTP · 3,036 people · 2019
Highest in the city: 95.47 µg/L — DAYSPRING SENIOR LIVING · 64 people · 2018
3/3 SYR4
Nitrite
52 µg/L 5.2%
of the EPA limit 1000 µg/L
Highest in the city: DAYSPRING SENIOR LIVING · 64 people · 2019
2/3 SYR4
Barium
46.35 µg/L 2.3%
of the EPA limit 2000 µg/L
Main supplier: HILLIARD WTP · 3,036 people · 2018
Highest in the city: 47.175 µg/L — DAYSPRING SENIOR LIVING · 64 people · 2018
3/3 SYR4
Total Haloacetic Acids (HAA5)
24.956 µg/L 42%
of the EPA limit 60 µg/L
Main supplier: HILLIARD WTP · 3,036 people · 2019
3/3 SYR4
Copper
13.74 µg/L 1.1%
of the EPA limit 1300 µg/L
Main supplier: HILLIARD WTP · 3,036 people · 2018
3/3 SYR4
Cyanide
8.605 µg/L 4.3%
of the EPA limit 200 µg/L
Main supplier: HILLIARD WTP · 3,036 people · 2018
1/3 SYR4
Xylenes, Total
7.958 µg/L 0.1%
of the EPA limit 10000 µg/L
Highest in the city: DAYSPRING SENIOR LIVING · 64 people · 2019
1/3 SYR4
Toluene
4.11 µg/L 0.4%
of the EPA limit 1000 µg/L
Highest in the city: DAYSPRING SENIOR LIVING · 64 people · 2019
1/3 SYR4
Antimony, Total
0.9900 µg/L 17%
of the EPA limit 6 µg/L
Main supplier: HILLIARD WTP · 3,036 people · 2018
Highest in the city: 3 µg/L — DAYSPRING VILLAGE · 121 people · 2018
2/3 SYR4
Selenium
1.17 µg/L 2.3%
of the EPA limit 50 µg/L
Main supplier: HILLIARD WTP · 3,036 people · 2018
Highest in the city: 2.2 µg/L — DAYSPRING SENIOR LIVING · 64 people · 2018
3/3 SYR4
Chromium
1.77 µg/L 1.8%
of the EPA limit 100 µg/L
Main supplier: HILLIARD WTP · 3,036 people · 2018
3/3 SYR4
Dalapon
0.7115 µg/L 0.4%
of the EPA limit 200 µg/L
Main supplier: HILLIARD WTP · 3,036 people · 2019
Highest in the city: 1.1 µg/L — DAYSPRING SENIOR LIVING · 64 people · 2018
3/3 SYR4
Ethylbenzene
0.9500 µg/L 0.1%
of the EPA limit 700 µg/L
Highest in the city: DAYSPRING SENIOR LIVING · 64 people · 2019
1/3 SYR4
Arsenic
0.8000 µg/L 8%
of the EPA limit 10 µg/L
Highest in the city: DAYSPRING VILLAGE · 121 people · 2018
1/3 SYR4
Lead
0.5000 µg/L 3.3%
of the EPA limit 15 µg/L
Main supplier: HILLIARD WTP · 3,036 people · 2018
2/3 SYR4
Di(2-ethylhexyl) Phthalate
0.3200 µg/L 5.3%
of the EPA limit 6 µg/L
Highest in the city: DAYSPRING VILLAGE · 121 people · 2018
1/3 SYR4
Methoxychlor
0.2270 µg/L 0.6%
of the EPA limit 40 µg/L
Highest in the city: DAYSPRING SENIOR LIVING · 64 people · 2019
1/3 SYR4
Mercury
0.2000 µg/L 10%
of the EPA limit 2 µg/L
Main supplier: HILLIARD WTP · 3,036 people · 2018
1/3 SYR4
Combined Uranium
0.1404 µg/L 0.5%
of the EPA limit 30 µg/L
Main supplier: HILLIARD WTP · 3,036 people · 2018
1/3 SYR4
Cadmium
0.1000 µg/L 2%
of the EPA limit 5 µg/L
Highest in the city: DAYSPRING VILLAGE · 121 people · 2018
1/3 SYR4
Bhc-Gamma
0.0990 µg/L 50%
of the EPA limit 0.2000 µg/L
Highest in the city: DAYSPRING SENIOR LIVING · 64 people · 2019
1/3 SYR4
Hexachlorocyclopentadiene
0.0350 µg/L 0.1%
of the EPA limit 50 µg/L
Highest in the city: DAYSPRING SENIOR LIVING · 64 people · 2018
1/3 SYR4
Lead
0.0020 mg/L 13%
of the EPA limit 0.0150 mg/L
Main supplier: HILLIARD WTP · 3,036 people · 2023
3/3 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Hilliard

SupplierPopulation served
HILLIARD WTP 3,036
DAYSPRING VILLAGE 121
DAYSPRING SENIOR LIVING 64

Frequently asked questions about Hilliard tap water

Is Hilliard tap water safe to drink?

EPA testing detected 25 contaminants in the water serving Hilliard. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Hilliard?

3 public water suppliers report drinking-water monitoring for Hilliard, Florida to the EPA. Each is listed above with its population served.

What contaminants are in Hilliard's water?

The contaminants EPA monitoring detected in Hilliard include Fluoride, Nitrate, TTHM, Nitrite, Barium. The full list, with the level at the main supplier and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.